Setting
Creating a configuration with the TSC commissioning wizard
34
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
In the register tab Local I/Os, the safe slots of TBPN-L5-4FDI-4FDX are configured.
Basic configuration
In the basic configuration, the safe inputs (FDI) at C0…C3 are defined as double channel forced,
safe inputs (dry contact). The safe in-/outputs (FDX) at C4…C7 are configured as safe outputs
according to PLe.
Channel
Type desig-
nation
I/O name
Device name
FDI0/1
E-stop
Safe input (dry contact)
Double channel forced
FDI2/3
E-stop
Safe input (dry contact)
Double channel forced
FDI4/5
E-stop
Safe input (dry contact)
Double channel forced
FDI6/7
E-stop
Safe input (dry contact)
Double channel forced
FDX8/9
Safe output Safe output
Safe output according to PLe (test pulse
every 500 milliseconds)
FDX10/11 Safe output Safe output
Safe output according to PLe (test pulse
every 500 milliseconds)
FDX12/13 Safe output Safe output
Safe output according to PLe (test pulse
every 500 milliseconds)
FDX14/15 Safe output Safe output
Safe output according to PLe (test pulse
every 500 milliseconds)
Complete the configuration with
OK
.
a
The basic configuration is applied.
a
The release circuits of the basic configuration are automatically created.