background image

Signal processor

MS96 for flow sensors

MS96-11EX0-R/230VAC

Type code

MS96-11EX0-R/230VAC

Ident no.

5231400

Ambient temperature

-20…60 °C

Operating voltage

198…242 VAC

No-load current I

0

ð

  28  mA

Output function

Relay output, changover contact

Device designation

É

 II(1) G D [EEx ia] IIC

Protection type

II(1) G D [EEx ia] II C

Ex approval acc. to conformity certificate

TÜV 96 ATEX 1098

Protection class

IP20

Protection class (terminals/housing)

IP20 / IP40

Design

terminal chamber

Dimensions

110 x 50 x 75 mm

Housing material

polycarbonate/ABS

Connection

terminal chamber

Indication: Drop below setpoint

LED red

Indication: Setpoint reached

LED yellow

Indication: Setpoint exceeded

4 x LEDs green

ATEX category II (1) G, Ex Zone 0

ATEX category II (1) D, Ex Zone 20

single-channel signal processor MS96

for connection of an intrinsically safe

flow control sensor in zone 0

adjustment via potentiometer

6 LEDs for display of the flow state

intrinsically safe control circuit, [EExia]

IIC

switch-off delay adjustable in a range of

0…25 s

wire-break monitoring

198…242 VAC

Changeover contact, relay output

Wiring diagram

Functional principle

Signal processors not only supply insertion
and inline sensors with voltage, they also pro-
cess and display the measured signals. De-
vices with MK96…, MS96… and MC96…
housing styles are available. The individual
housing styles are designed for different oper-
ating voltages and feature various output and
supplementary functions. For intrinsically safe
flow sensors it is required to use signal pro-
cessors with intrinsically safe control circuits
of the series MS96…Ex… and MC96…Ex… .

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание MS96-11EX0-R/230VAC

Страница 1: ...D Ex Zone 20 single channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit EExia IIC switch off delay adjustable in a range of 0 25 s wire break monitoring 198 242 VAC Changeover contact relay output Wiring diagram Functional principle Signal processors ...

Страница 2: ...cally safe circuits mounting of external connection parts as well as the characteristics and laying of cables Cables and terminals with intrinsically safe circuits must be marked They should be separated from non intrinsically safe circuits or must fea ture appropriate insulation EN 60079 14 Observe the prescribed clearances to earthed components and connections of other devices to the intrinsical...

Страница 3: ...D Ex Zone 20 single channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit EExia IIC switch off delay adjustable in a range of 0 25 s wire break monitoring 99 121 VAC Changeover contact relay output Wiring diagram Functional principle Signal processors n...

Страница 4: ...cally safe circuits mounting of external connection parts as well as the characteristics and laying of cables Cables and terminals with intrinsically safe circuits must be marked They should be separated from non intrinsically safe circuits or must fea ture appropriate insulation EN 60079 14 Observe the prescribed clearances to earthed components and connections of other devices to the intrinsical...

Страница 5: ... Ex Zone 20 single channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit EExia IIC switch off delay adjustable in a range of 0 25 s wire break monitoring 21 28 VDC Changeover contact relay output Wiring diagram Functional principle Signal processors not...

Страница 6: ...cally safe circuits mounting of external connection parts as well as the characteristics and laying of cables Cables and terminals with intrinsically safe circuits must be marked They should be separated from non intrinsically safe circuits or must fea ture appropriate insulation EN 60079 14 Observe the prescribed clearances to earthed components and connections of other devices to the intrinsical...

Отзывы: