User manual

BLCDN-4M12S-4AO-V

Содержание BLCDN-4M12S-4AO-V

Страница 1: ...User manual BLCDN 4M12S 4AO V...

Страница 2: ...nd product names are trademarks or registered trade marks of the owner concerned Hans Turck GmbH M lheim an der Ruhr All rights reserved including those of the translation No part of this manual may b...

Страница 3: ...act High signal variety in a compact design 6 4 Technical data 7 5 Fieldbus and I O connections 8 5 1 Pinning and wiring diagram 8 6 Commissioning 9 6 1 Address setting 9 6 2 Setting the transmission...

Страница 4: ...of the low low voltage for the 24 volt supply Only use power supply units complying with IEC 60 364 4 41 VDE 0 100 Part 410 or HD 384 4 41 S2 Deviations of the mains voltage from the rated value must...

Страница 5: ...ll notes that indicate a potential hazard This can refer to possible danger to personnel and dam ages to the system hardware and software and to the facility NOTE This sign can be found next to all ge...

Страница 6: ...e can take one gateway with up to 32 extension modules max 512 I O points For applications with low signal density and limited mounting space BL compact is an efficient alternative because basically a...

Страница 7: ...ble MACID 81 99 Vendor Specific Fieldbus addressing 2 decimally coded rotary switches Service interface RS232 interface Fieldbus connection technology 2 x M12 5 pin Fieldbus termination external Analo...

Страница 8: ...an der Ruhr Witzlebenstra e 7 Tel 0208 4952 0 Fax 0208 4952 264 more turck com www turck com 5 Fieldbus and I O connections 5 1 Pinning and wiring diagram Fieldbus accessories DeviceNet fieldbus cable...

Страница 9: ...ides automatic transmission rate detection The bit rate can be changed via the standard ODVA DeviceNet Class Class 0x03 In stance 0x01 Attribute 0xx02 6 3 Field bus termination If the module is used a...

Страница 10: ...he modules to your fieldbus line The EDS files can be downloaded from www turck com 6 6 Vendor Specifc Classes VSCs BL compact modules for DeviceNet are based on the communications adapter profile acc...

Страница 11: ...TM The system configuration parameterization and diagnostics are done via graphical interfaces based on FDT DTM technology The DTMs can be integrated in any FDT frame application for configuration com...

Страница 12: ...LASHING Force mode active MNS OFF No connection GREEN ON Connection established GREEN FLASHING 1 Hz No connection established device OK RED ON Duplicate MAC ID RED FLASHING Connection time out IO GREE...

Страница 13: ...Overflow Underflow Reserved Measuring Range Exceeded Ch 2 4 Hardware Failure Reserved Overflow Underflow Reserved Measuring Range Exceeded Ch 3 5 Hardware Failure Reserved Overflow Underflow Reserved...

Страница 14: ...2 hold outputs BUS OFF irtp 03 01 03 0 holf CAN chip in BUS OFF state 1 reset CAN chip default setting 10 2 4AO V Parameters Parameter Description 4AO V output AO 0 fault mode 76 01 7D to 4AO V output...