d a t a s h e e t
TXP-151
T X P S E R I E S E N G I N E E R I N G I N F O R M A T I O N
page 3
FREQUENCY
RESPONSE
(FULL RANGE)
FREQUENCY
RESPONSE
(HIGH PASS)
100
1 kHz
10
20
Frequency
50
200
500
2
5
20 Hz
0.2%
1.0%
Ref.
10% Power
Fundamental
1W/1M
Sensitivity
3rd Harmonic
10% Power
2nd Harmonic
10% Power
120
110
100
90
80
70
60
50
Sound Pressure Level in dB
Distortion %
100
1 kHz
10
20
Frequency
50
200
500
2
5
20 Hz
0.2%
1.0%
Ref.
10% Power
Fundamental
1W/1M
Sensitivity
3rd Harmonic
10% Power
2nd Harmonic
10% Power
120
110
100
90
80
70
60
50
Sound Pressure Level in dB
Distortion %
Impedance
A constant current circuit was used to measure the impedance.
Frequency response
The frequency response
shown was obtained by feeding a swept sine wave through the system in a half space environment. The position of the
microphone was vertically on-axis at a distance of 2 metres, then scaled to represent 1 metre.
2nd & 3rd Harmonic Distortion
Distortion measurements were obtained using an Audio Precision harmonic distortion analysis system and comply with
AES recommendations for enclosure measurement (AES paper ANSI S4-26-1984).
Data Conversion
All graphs were digitally
generated using the APEX custom software system, designed to translate data derived from Audio Precision ‘System
One’ test equipment into AutoCAD™. This program enables graphical information to be plotted to a high degree of
accuracy.
NOTES ON
MEASUREMENT
CONDITIONS