EN
BM 30
IS13/02 - 561291
8 - MAINTENANCE
Cap. 8 -
Pag.
11/15
THIS MANUAL IS PROPERTY OF
-
ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
- Re-position and fasten the fixed bodywork with specific screws.
- Start the engine and make the hydraulic pump turn for a few minutes empty, checking the oil level through the sight glass
(FIG.58-REF.5); top-up if level is below the sight glass.
8.8
Replacing the additive metering pump
The following steps must be carried out with the machine switched off.
- release the plug (FIG.59-REF.1).
- Loosen the bolt (FIG.59-REF.3).
- Remove the flange (FIG.59-REF.2).
- Replace the pump.
- Mount the new pump; if necessary remove the cover to hook rotor to the shaft.
1
3
2
A
B
0÷3 mm
C
FIG.59 FIG.60
The stator usually works at half the rate of the auger. Accordingly, it may be necessary to replace only the stator while leaving
the auger in place.
- Uninstall the pump from the machine (see above).
- Put the pump in a vice and remove the auger (FIG.60-REF.A).
- Lubricate the auger and the opening in the stator with Vaseline (DO NOT USE OIL OR GREASE, USE ONLY VASELINE*).
- Partially introduce the auger inside the countersunk opening.
- Screw the rotor; the rotor end must get out from rotor max. 3 mm (FIG.60-REF.C).
*TURBOSOL suggests vaseline PAKELO VASELBA B.
8.8.1
Greasing dosing pump
Grease dosing pump at the end of work session.
Grease dosing pump by the greaser point pictured on FIG.61.
TURBOSOL suggests grease TOTAL MULTIS EP1