19
Failure Display and Inspection
If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes:
Problem
Possible causes
What to do
F3-F8
Temperature sensor failure
Please contact the supplier.
F9-FE
Temperature sensor of the
IGBT failure.
Please contact the supplier.
E1/E2
Abnormal supply voltage
Please inspect whether power
supply is normal.
Power on after the power
supply is normal.
E3/E4
Abnormal temperature
Please inspect the pot.
E5/E6
Bad induction hob heat
radiation
Please restart after the
induction hob cools down.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages
to the induction hob.
Technical Specification
Cooking Hob
TIM29
Cooking Zones
2 Zones
Supply Voltage
220-240V~ 50/60Hz
Installed Electric Power
2800 W
Product Size L×W×H(mm)
288X520X56
Building-in Dimensions A×B (mm)
268X500
Weight and Dimensions are approximate. Because we continually strive to
improve our products we may change specifications and designs without prior
notice.
Installation
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.