1. SPECIFICATION .......................................................................................... 2

2. SERIAL NUMBER ........................................................................................ 2

3. INSTALLATION ............................................................................................ 3

4. CLEANING ................................................................................................... 4

5. BASIC OPERATION

5-1. REFRIGERATORS ........................................................................... 5~8

5-2. FREEZERS..................................................................................... 9~12

6. BEFORE REQUESTING SERVICE ........................................................... 13

7. WARRANTY......................................................................................... 14~16

PAGE

Refrigerators

MODEL COMP 

H.P. 

V/Hz  REFRIGERANT AMPS 

WEIGHT

TSR-23SD*

1/4 115V/60Hz 

R-134a  5.5A 

274lbs

TSR-35SD

1/3 115V/60Hz 

R-134a  9A 357lbs

TSR-49SD

1/3 115V/60Hz 

R-134a  9.2A 

427lbs

TSR-72SD

1/2 115V/60Hz 

R-134a  11.3A 

602lbs

MODEL COMP 

H.P. 

V/Hz  REFRIGERANT AMPS 

WEIGHT

TSF-23SD

1/2 115V/60Hz 

R-134a  7.8A 

293lbs

TSF-35SD

3/4 115V/60Hz 

R-134a  10A 390lbs

TSF-49SD

3/4 115V/60Hz 

R-134a  10.5A 

457lbs

TSF-72SD

1

1/4

 

115V/208~230/60Hz R-134a 

10.4A 

639lbs

The serial number is located on the data label inside.

Please retain the unitʼs serial number for service purpose.

Freezers

2

CONTENTS

SPECIFICATION

SERIAL NUMBER

Содержание TSF-35SD

Страница 1: ...tainless Steel Interior and Exterior www turboairinc com SOLID DOOR REFRIGERATOR TSR 23SD TSR 35SD TSR 49SD TSR 72SD SOLID DOOR FREEZER TSF 23SD TSF 35SD TSF 49SD TSF 72SD Refrigerator Freezer Install...

Страница 2: ...5V 60Hz R 134a 9A 357lbs TSR 49SD 1 3 115V 60Hz R 134a 9 2A 427lbs TSR 72SD 1 2 115V 60Hz R 134a 11 3A 602lbs MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TSF 23SD 1 2 115V 60Hz R 134a 7 8A 293lbs TSF...

Страница 3: ...contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this un...

Страница 4: ...quently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure that the power cord is connected to the proper...

Страница 5: ...e setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Sensor 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set level toward 1 fo...

Страница 6: ...GERATOR 9 TEMPERATURE T C 8 7 6 5 4 3 2 1 FAN DOOR TURBO COOLING TEMPERATURE F TEMP SETTING TURBO COOLING FAN RUNNING DOOR OPENING TURBO COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 7 INNER TEMP SEE...

Страница 7: ...de the compressor will return to the normal operation 3 During the Turbo Cooling mode works the temperature Up Down button will not affect the compressor s operation 1 By pushing the up down button yo...

Страница 8: ...will be turned on 2 Evaporator fan motor is activated when the door both doors for TSR 49SD all three doors for TSR 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 I...

Страница 9: ...B F Sensor 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperatures and toward 9 for lower temperatures 6 The interior light is activate...

Страница 10: ...ER 9 TEMPERATURE D F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST FAN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 11 INNER TEMP SEE...

Страница 11: ...lighted higher level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 times per a day 2 If it is necessary to change the intervals of defros...

Страница 12: ...be turned on 2 Evaporator fan motor is activated when the door both doors for TSF 49SD all three doors for TSF 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 In cas...

Страница 13: ...tly The back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open...

Страница 14: ...fter shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or...

Страница 15: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLI...

Страница 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Отзывы: