Turbo Air TSF-35SD Скачать руководство пользователя страница 15

Turbo airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional

limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by
this warranty.

1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original

purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN
MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

2. NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS OR

SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES OR DAMAGES
ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION
FAILURE.

3. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE,

FLOOD, ACTS OF GOD. TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determines
have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or
installation, fire, flood, or an Act of God.

4. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO

OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, EXCEPT THE THREE(3) YEAR WARRANTY AND THE
ADDITIONAL TWO(2) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF.

5. TRANSPORTATION COSTS. Turbo Air will accept parts covered under this warranty freight collect, provided that shipment

has received prior approval. Turbo Air is not responsible for any other transporation costs, but will ship freight collect parts
either repaired or replaced under these warranties.

6. WARRANTY CLAIMS. All claims should include: model number of the cooler, the serial number of the cabinet, proof of

purchase, date of installation, and all pertinent information supporting the existence of the alleged defect. Any action or breach
of these warranty provisions must be commenced within three (3) year after that cause of action has accrued.

What is NOT covered by this warranty

4184 Conant St.,
Long Beach, CA 90808

TEL: 310-900-1000
FAX: 310-900-1077
TOLL FREE: 1-800-627-0032

(U.S.A. & Canada)

http://www.turboairinc.com

Содержание TSF-35SD

Страница 1: ...tainless Steel Interior and Exterior www turboairinc com SOLID DOOR REFRIGERATOR TSR 23SD TSR 35SD TSR 49SD TSR 72SD SOLID DOOR FREEZER TSF 23SD TSF 35SD TSF 49SD TSF 72SD Refrigerator Freezer Install...

Страница 2: ...5V 60Hz R 134a 9A 357lbs TSR 49SD 1 3 115V 60Hz R 134a 9 2A 427lbs TSR 72SD 1 2 115V 60Hz R 134a 11 3A 602lbs MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TSF 23SD 1 2 115V 60Hz R 134a 7 8A 293lbs TSF...

Страница 3: ...contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this un...

Страница 4: ...quently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure that the power cord is connected to the proper...

Страница 5: ...e setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Sensor 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set level toward 1 fo...

Страница 6: ...GERATOR 9 TEMPERATURE T C 8 7 6 5 4 3 2 1 FAN DOOR TURBO COOLING TEMPERATURE F TEMP SETTING TURBO COOLING FAN RUNNING DOOR OPENING TURBO COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 7 INNER TEMP SEE...

Страница 7: ...de the compressor will return to the normal operation 3 During the Turbo Cooling mode works the temperature Up Down button will not affect the compressor s operation 1 By pushing the up down button yo...

Страница 8: ...will be turned on 2 Evaporator fan motor is activated when the door both doors for TSR 49SD all three doors for TSR 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 I...

Страница 9: ...B F Sensor 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperatures and toward 9 for lower temperatures 6 The interior light is activate...

Страница 10: ...ER 9 TEMPERATURE D F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST FAN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 11 INNER TEMP SEE...

Страница 11: ...lighted higher level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 times per a day 2 If it is necessary to change the intervals of defros...

Страница 12: ...be turned on 2 Evaporator fan motor is activated when the door both doors for TSF 49SD all three doors for TSF 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 In cas...

Страница 13: ...tly The back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open...

Страница 14: ...fter shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or...

Страница 15: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLI...

Страница 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Отзывы: