background image

8

OPERATING INSTRUCTIONS

The shelves can be installed slanted or straight. To make the shelf slanted do the
following.

 

a. Shelf needs to be removed from shelf support.

 

b. Shelf support needs to be held at each end.

 

c. Shelf support needs to be lifted at the back till bracket can be inserted into self

 

    standard slots.

Refer to drawing of page 4.

SHELF PLACEMENT :

When replacing lights use same model of light installed in Bakery Case. Using wrong
wattage can cause ballast to burn out or light not work.

To remove light there is two lamp holders one at each end of light. One has a spring in
socket. Push light toward spring loaded lamp holder till other end of light pops out of
other lamp holder.

Remove light from lamp shield and insert new light into lamp shield. Reinsert into lamp
holders. Never install lamp without shield.

REPLACEMENT OF LIGHT

Shelves can be adjusted up or down. To move shelves do the following ;

 

a. Lights must be turned off.

 

b. Grasp plug for light cord and unplug.

 

c. Shelves must be removed from shelf support.

 

d. Hold onto each end of shelf support.

 

e. Shelf support needs to be moved up until it can be removed from shelf standard.

ADJUSTING SHELF LEVEL

Содержание TCB-5R

Страница 1: ...ses Bakery Cases Installation and Operation Manual CAUTION PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting to install or operate this e...

Страница 2: ...AGING MATERIAL 4 LIGHTS 4 SHELVES 4 ELECTRICAL INFORMATION 5 WIRING DIAGRAM 6 OPERATING INSTRUCTIONS 7 8 FRONT CURVED GLASS 9 MAINTENANCE CLEANING 10 11 TROUBLE SHOOTING 12 WARRANTY MODEL COMP H P V H...

Страница 3: ...nce 86 inch at the top 20 inch at the rear and 12 inch at the cash inside CAUTION Damage to case and glass can result if pushed on Do not push curved glass end glass doors or door frames Do not place...

Страница 4: ...shelves in desired position front glass must be open and rear doors removed Remove doors by lifting upwards and then out of bottom track one at a time Put doors in a safe location Lift front glass up...

Страница 5: ...cian Electrical data is located next to electrical junction box see drawing The Bakery Case comes with a power cord Cord is 9 8 feet long The plug is a Improper electrical connections can result in se...

Страница 6: ...6 WIRING DIAGRAM TCB 5R...

Страница 7: ...LS 5 The thermostat controls compressor s on off by sensing inside temperature THERMOMETER Display changes temperature approximately every two second NOTE Before placing goods to Bakery Case wait for...

Страница 8: ...light not work To remove light there is two lamp holders one at each end of light One has a spring in socket Push light toward spring loaded lamp holder till other end of light pops out of other lamp...

Страница 9: ...trained personnel should lift curved glass Under normal use hinges will last many years If any of the following problems occur please call Customer Service a Front curved glass closed rapidly b Front...

Страница 10: ...sanitized Bakery Case Procedure may have to be done more than once a week if necessary 1 Clean front glass with window cleaner 2 Clean exterior with warm soapy water Wipe down with damp cloth 1 Remove...

Страница 11: ...brush or vacuuming with wet dry vacuum Condenser is black and looks like a radiator This should be cleaned every month or as necessary Keeping clean allows for maximum cooling of unit and long life of...

Страница 12: ...kery Case Unit should be between 38 and 42 degrees 5 Check that air is flowing inside front of Bakery Case If there is no air flow or air is felt on only one side this is due to anti moisture fans are...

Страница 13: ...er shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or co...

Страница 14: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLI...

Страница 15: ...R404A or R134a refrigerant and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opene...

Отзывы: