7
Turbo Air
1. If you push the Q.C. (Q.F.) button, the compressor will run continuously to bring down
the temperature more quickly. (max.comp.run time = 120 min.)
2. If you push the Q.C.(Q.F.) button again during Quick Cooling(Freeze) mode, the
compressor will return to the normal operation.
3. While the Quick Cooling(Freeze) mode is in place, the temperature Up/Down button
will not affect the compressor’s operation.
QUICK COOLING / QUICK FREEZE
1. By pushing the up/down button, you can set the inside temperature level from ‘1’ to ‘8’.
2. If you want lower temperatures, push the Up button to light the higher level numbers.
UP/DOWN BUTTON (Temperature control button)
1. The electronic defrost controller is set at the factory to provide a defrost cycle every 6
hours (4 times per a day).
2. Once all frost is eliminated, the temperature continues to rise until it reaches 50°F
(10°C). When this temperature is sensed by the defrost limit control, the defrost
control changes to refrigeration mode.
3. The panel displays “
” during the defrost cycle.
DEFROST