background image

12

OPERATING INSTRUCTIONS

Level and set your sushi cases in place. Connect all necessary electrical 

connections. Your sushi cases should now be ready for use.

POWER SWITCH (SAK-50*-N, SAK-60*-N, SAK-70*-N) 

Located at the bottom of rear panel.

POWER SWITCH (SAS-50*-N, SAS-60*-N, SAS-70*-N) 

Located at the Top of rear panel.
LIGHT SWITCH (SAS-50*-N, SAS-60*-N, SAS-70*-N) 

Located at the Top of rear panel.
TEMPERATURE CONTROL (SAS-50*-N, SAS-60*-N, SAS-70*-N) 

Located at the Top of rear panel.

HOW TO SET THE TEMPERATURE

PRODUCT PLACEMENT

Overloading of product or placing products against the back wall or suction grill may 

cause disruption to air flow, which may cause the unit to not cool properly.

NOTE

• Do not place products into your merchandiser until the desired temperature is reached.

• Do not place hot products into the merchandiser.

1. Press the SET button          for one second to check the temperature setting. 
2. The display panel shows the current temperature.
3. To change the temperature, press the UP        or DOWN        button and press 
    the SET button          when adjustment is complete. 
4. The temperature setting has been changed and the display panel shows

    the current temperature.

set

set

MANUAL DEFROST

1. Press the DEFROST button         for three seconds to begin a manual defrost. 
2. Defrost mode will turn off automatically when it is complete.
3. To manually stop the defrosting process, hold the DEFROST button

    

    for three seconds.

Содержание Direct Cooling Series

Страница 1: ...Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment SAK 50R N SAK 60R N SAK 70R N SAK 50L N SAK 60L N SAK 70L N SAS 50R N SAS 60R N SAS 70R N SAS 50L N SAS 60L N SAS 70L N www turboairinc com ...

Страница 2: ...TY INFORMATION Safety Precautions Installation Usage Proper Disposal of Old Appliance Before You Call for service SPECIFICATIONS INSTALLATION OPERATING INSTRUCTIONS MAINTENANCE CLEANING TROUBLESHOOTING WARRANTY WARRANTY REGISTRATION CARD 3 4 5 6 9 10 11 12 13 14 15 16 19 ...

Страница 3: ...d knowledge are not included in this manual and are not required to be included Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This manual uses the following safety symbols These safety symbols with the words of DANGER WARNING or CAUTION alert users of the potential hazards that could cause injury or even death DANGER WARN...

Страница 4: ...Do not puncture refrigerant tubing CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safety precautions must be followed CAUTION Risk of fire or explosion due to puncture of refr...

Страница 5: ...ce The amount of refrigerant in your particular appliance is shown on the label inside the cabinet Never start up an appliance showing any signs of damage When in doubt contact a qualified service professional In case of any hazardous activities such as fire or explosion move the unit away from any source of ignition to a well ventilated area Further service and repair must be done by a qualified ...

Страница 6: ...ammable substances in the refrigerator The storage of benzene thinner alcohol ether LP gas or other explosive substances may cause an explosion Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance as well as any other appliances The appliance is not intended for use by children without supervision Do not allow children to climb stand or hang on the r...

Страница 7: ...any containers filled with water on top of the appliance If the water spills onto any electrical parts it may lead to fire or electric shock Do not attempt to repair disassemble or alter the appliance It may cause fire or abnormal operations which may lead to injury Unplug the refrigerator before making repairs replacing a light bulb or cleaning Plug into a grounded 3 prong outlet Do not remove th...

Страница 8: ...rwise there is a risk of fire Do not insert your hand into the bottom area of appliance Any sharp edges may cause personal injury After unplugging the appliance wait at least five minutes before plugging it back in Abnormal operation of the freezer may cause material damage If the appliance is not used for a long period of time unplug it from the power supply Any deterioration in the insulation ma...

Страница 9: ... back of the appliance may not be damaged Information concerning collection schedules or locations can be obtained from the local disposal authorities PROPER DISPOSAL OF OLD APPLIANCE BEFORE YOU CALL FOR SERVICE For environmental purposes refrigeration appliances must be properly disposed This applies to your old appliance and at the end of its service life for your new appliance as well Before co...

Страница 10: ... SAK 70R N 481 4 x 141 8 x 111 2 4 6A 76 lbs 115V 1PH 60HZ 4 6A NEK6152U R 290 87 lbs 4 6A 98 lbs 593 4 x 141 8 x 111 2 711 4 x 141 8 x 111 2 Model Dimension WxDxH in Electricity Full Load Amperes Compressor Refrigerant Lighting Defrost Net Weight SAS 50L N SAS 50R N SAS 60L N SAS 60R N SAS 70L N SAS 70R N 465 8 x 141 2 x 131 2 3A 8 4Wx1 76 lbs 3A 14 7Wx1 98 lbs 115V 1PH 60HZ 3A NEK6152U R 290 11 ...

Страница 11: ...tive humidity RECOMMENDED OPERATING CONDITIONS A Sushi cases should be installed on well leveled table or flat location B If unit is not leveled water will not drain properly Leveling legs can be adjusted accordingly LEVELING OF SUSHI CASES Customer is responsible for checking for damage First inspect crate as soon as it arrives Prior to signing acceptance of shipment if the crate is damaged make ...

Страница 12: ...l may cause disruption to air flow which may cause the unit to not cool properly NOTE Do not place products into your merchandiser until the desired temperature is reached Do not place hot products into the merchandiser 1 Press the SET button for one second to check the temperature setting 2 The display panel shows the current temperature 3 To change the temperature press the UP or DOWN button and...

Страница 13: ...ter and mild detergent e Wipe with damp cloth Do not leave soap residue CLEAN YOUR SUSHI CASES THOROUGHLY BEFORE FIRST USAGE CLEANING THE CONDENSER COIL How to remove Louver 1 3 2 1 Disconnect the electrical power from the unit 2 Lift up the Louver to release from the body 3 Pull the Louver toward you 4 Pull down 5 Brush off dust and lint from the finned condenser coil 6 When finished install louv...

Страница 14: ...S NOT FUNCTIONING a Check to see that the breaker hasn t tripped b Check that enough power is BEING supplied to the unit c Check that the power switch is on Ⅱ SUSHI CASES IS WARM a Check the condenser to see if it is clean b Check that the inner airflow is not being blocked by products Ⅲ LIGHTS ARE NOT WORKING SAS models only a Check that light switch is on b Check that the lights are placed in th...

Страница 15: ...y not be considered as proper installation Additional Three Year Compressor Warranty In addition to the two 2 year warranty stated above Turbo Air warrants its hermetically sealed compres sor to be free from defects in both material and workmanship under normal and proper use and mainte nance service for a period of three 3 additional years from the date of original installation but not to exceed ...

Страница 16: ...AGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD OR IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE THE USE OF EXTENSION CORDS LOW VOLTAGE OR VOLTAGE DROPS TO THE UNIT Use of NON OEM parts without manufacturer s approval may void cabinet warranty NO IMPLIED WARRANTY OF MERCHA...

Страница 17: ...17 NOTE ...

Страница 18: ...18 NOTE ...

Страница 19: ... www turboairinc com registration within 7 days from the date of purchase Failure to comply may result in your warranty being voided Date of Purchase Name of the Dealer City State Zip Code Turbo Air Inc 4184 E Conant St Long Beach CA 90808 Toll Free 1 800 381 7770 Fax 310 900 1033 Email warranty turboairinc com MAIL CARD IMMEDIATELY OR GO TO ONLINE REGISTRATION AT www turboairinc com registration ...

Страница 20: ...www turboairinc com 4184 E Conant St Long Beach CA 90808 Toll Free 1 800 381 7770 Fax 310 900 1033 Email warranty turboairinc com ...

Отзывы: