Troubleshooting
Fault
Possible cause
Solution
Water changes color or be-
comes cloudy.
Rower is in direct sunlight or
has not had water treatment.
Change rower location to
reduce direct exposure to
sunlight.
Add water treatment or
change tank water as di-
rected in the water treatment
section of this manual.
Rower belt slipping off belt /
bungee pulley.
Bungee cord not under
enough tension.
Tighten bungee cord follow-
ing the instructions in
"Re-attaching the rowing
belt” - step 8 of this manual.
Front of rower lifts slightly
during vigorous rowing.
Vertical seat rail tensioning
bolt (M10x150mm) is too
loose.
Tighten bolt 1/2 turn and row
again. Tighten as needed
until problem stops.
Over tightening this bolt can
damage the seat rail. Only
tighten bolt in small incre-
ments until fault is corrected.
The rowing console
does not illuminate after bat-
tery installation.
Batteries installed incorrectly
or need replacing.
Reinstall batteries in correct
position and try again.
If the LCD screen fails to illu-
minate, try rotating the bat-
teries slightly in the console.
If this fails, contact your local
service center.
The rowing console screen
illuminates, but does not
register when rowing.
Loose or failed connection.
Check that the console lead
is connected properly. If it is
connected then contact your
local service center.