background image

CPA6

User Operating Instructions

TO SET THE SYSTEM

(Part Set facility not programmed)

1. Ensure that all monitored areas are secured

2. The Panel display should show the date and time

and ‘System Open’

3. Enter your 4 digit code. The Panel display will show

‘Do you want to set the system?’;

4. Press YES/ENTER. The Panel display will show ‘Leave

via Exit Route’;

5. Exit sounder will sound. Leave via the designated

exit route and close the last exit;

6. When the sounder stops the system is Set to guard

the premise (the display shows ‘System Set’).

TO UNSET THE SYSTEM

1. Enter the premises via the normal entry route and

go directly to the Control Panel. The entry sounder
will sound;

2. Enter your 4 digit code; The sounder will stop and

the system will be Unset and no longer guarding the
premises. The display will show the date and time
and ‘System Open’;

3. Deviating from the entry route or exceeding the

entry time will cause an alarm condition.

ALARM CONDITION - TO UNSET THE SYSTEM.

1. Enter the premises via the normal Entry route and

go directly to the Control Panel. The entry sounder
will sound;

2. Enter your 4 digit code. Sounder will change to fault

tone and the display will show details of the last
alarm;

3. Press YES/ENTER to display other alarms;

4. After the first alarm is displayed the display will show:

‘Call Alarm Company to reset’ OR ‘System Re-arm’;

5. Call for an Engineer to reset the panel OR enter your

4 digit code;

6. If code is entered the display will show ’Do you want

to set the system?’;

7. Enter your 4 digit code again. System will be Unset

and no longer guarding the premises. Display will
show date and time and ‘System Open’.

TO PART SET THE SYSTEM (Only if this facility has
been programmed)

1.

Ensure that all monitored areas, except those to
be shunted (excluded), are secured;

2.

The panel display should show the date and time
and ‘System Open’;

3.

Enter your 4 digit code. The panel display will show
‘Do you want to set the system?’;

4.

Press YES/ENTER. The panel display will show ‘Do

you want any circuits shunted?’;

5.

Press NO and leave by the designated exit route
OR press YES/ENTER;

6.

If YES is pressed Display will show: ‘Shunt

Routine:-key in zone no (NO to exit)’;

7.

Press zone number (1-6) required. Display will
show ‘Z (No of zone) 1 2 3 - 0 (circuits)’ and the
Circuits that may shunted (excluded) will flash;

8.

Press circuit numbers that are to be shunted
(excluded). Display will indicate shunted circuits
with ‘s’ Press YES/ENTER;

9.

Display will show; ‘shunt Routine; - key in zone no

(NO to exit)’. Repeat steps 6 to 8 for other zones
and circuits if required;

10. Press NO. Display will show ‘leave via exit route’;

11. Exit sounder will sound. Leave via the designated

exit route and close the last exit;

12. When the sounder stops the system is Part Set to

partially guard the premises.

FAULT CONDITIONS

1. A Fault condition is indicated by the fault sounder

and a displayed message. The following faults
may occur;

2. Circuits are in alarm when attempting to set the

system. The affected circuits will be displayed
(Zone XX cct YY) and they must be corrected
before the system will set;

3. Departing from the exit route during the setting

procedure. The affected circuits will be displayed
(Zone XX cct YY) and they must be corrected
before the system will set;

4. Exceeding the time limit or not closing all exit route

devices if Timed Exit is used. The display will
show ‘Time-out Exit’ and the setting procedure
must be re-started;

5. If an incorrect code is entered wait 5 seconds then

re-enter the correct code.

CPA6

14 of 16

496524 Issue A

Содержание CPA6

Страница 1: ...CPA6 Installation User Guide Compatible Equipment CPA6 OM Output Module 9040 Loudspeaker DC54 58 Digital Communicators Stand Alone Only 496524 Issue A 1 of 16 CPA6...

Страница 2: ...ection circuits may be connected 10 per zone interfaced via remotely positioned Zone Expansion Module or ZEM ENGLISH TEXT DISPLAY Provides fully detailed information of system status detection circuit...

Страница 3: ...en the system is in the test set condition this definition is used TYPE 2 24 hour Circuit This type is selected when continuously monitored detectors are connected typically fire doors tube and wire f...

Страница 4: ...nals providing the end of line resistor Detection circuit wiring to Z E M s is via terminals Loop A and Loop B and the E O L resistors must be remote from the Z E M fitted Outputs P A This drives high...

Страница 5: ...CLK 0 Loop A Loop B 0 CLK CLK 0 Loop A Loop B 0 CLK 2 off connectors for use as Junction Block for 12V auxiliary supply 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 NOTE Up to Z E M s may be fitted to zone...

Страница 6: ...ain Audible L P A Alarm O P Main Audible L TYPE 5 EXIT ENTRY CIRCUIT 24Hr Fault O P Fault Audible NL SHUNTED BY PANEL Main Alarm O P Main Audible L SHUNTED BY PANEL TYPE 6 LAST EXIT SHUNT LOCK CIRCUIT...

Страница 7: ...SE 2 Is rated at 1A and is of the Anti Surge type Its function is to protect the supply to the CPA6 circuitry from overloads Failure of FS2 will result in the CPA6 display blanking and the keypad tone...

Страница 8: ...of the year Enter the month number of the year via the keypad 01 JANUARY etc As keys are pressed the display will show the month number When this is correct press the YES ENTER key Enters the display...

Страница 9: ...number of detection circuits that the panel identifies on Zone 2 REPEAT STEP 21 FOR ZONES 2 TO 6 The display shows the number of detection circuits that the panel identifies on the last Zone Zone 6 Co...

Страница 10: ...t by subscriber or by Engineer into memory and initiates the next step of commissioning The routine first assumes that P A alarms operate the main alarm audibles following a preset delay during the sy...

Страница 11: ...ER key operated If entry to the premises is to be timed then enter the required entry time in seconds via the keypad Registers that the alarm system has infinite entry time As keys are pressed the dis...

Страница 12: ...r information from the keypad The P A Code is a 4 digit keypad code which whenever operated activates the panels P A output The Code is particularly useful to a subscriber OPENING the alarm system und...

Страница 13: ...ers User code x in the panel s memory Selecting this User routine will enable the alarm system to be fully tested and set opened by the Engineer without knowledge of any user Code The commissioning ro...

Страница 14: ...nly if this facility has been programmed 1 Ensure that all monitored areas except those to be shunted excluded are secured 2 The panel display should show the date and time and System Open 3 Enter you...

Страница 15: ...panel display will show Do you want to set the system 4 Press NO The display will show Do you want Tests Press YES ENTER 5 The display will show Do you want Bell Test 6 Press YES ENTER The display wil...

Страница 16: ...CPA6 CPA6 16 of 16 496524 Issue A This page intentionally left blank...

Отзывы: