CPA6
User Operating Instructions
TO SET THE SYSTEM
(Part Set facility not programmed)
1. Ensure that all monitored areas are secured
2. The Panel display should show the date and time
and ‘System Open’
3. Enter your 4 digit code. The Panel display will show
‘Do you want to set the system?’;
4. Press YES/ENTER. The Panel display will show ‘Leave
via Exit Route’;
5. Exit sounder will sound. Leave via the designated
exit route and close the last exit;
6. When the sounder stops the system is Set to guard
the premise (the display shows ‘System Set’).
TO UNSET THE SYSTEM
1. Enter the premises via the normal entry route and
go directly to the Control Panel. The entry sounder
will sound;
2. Enter your 4 digit code; The sounder will stop and
the system will be Unset and no longer guarding the
premises. The display will show the date and time
and ‘System Open’;
3. Deviating from the entry route or exceeding the
entry time will cause an alarm condition.
ALARM CONDITION - TO UNSET THE SYSTEM.
1. Enter the premises via the normal Entry route and
go directly to the Control Panel. The entry sounder
will sound;
2. Enter your 4 digit code. Sounder will change to fault
tone and the display will show details of the last
alarm;
3. Press YES/ENTER to display other alarms;
4. After the first alarm is displayed the display will show:
‘Call Alarm Company to reset’ OR ‘System Re-arm’;
5. Call for an Engineer to reset the panel OR enter your
4 digit code;
6. If code is entered the display will show ’Do you want
to set the system?’;
7. Enter your 4 digit code again. System will be Unset
and no longer guarding the premises. Display will
show date and time and ‘System Open’.
TO PART SET THE SYSTEM (Only if this facility has
been programmed)
1.
Ensure that all monitored areas, except those to
be shunted (excluded), are secured;
2.
The panel display should show the date and time
and ‘System Open’;
3.
Enter your 4 digit code. The panel display will show
‘Do you want to set the system?’;
4.
Press YES/ENTER. The panel display will show ‘Do
you want any circuits shunted?’;
5.
Press NO and leave by the designated exit route
OR press YES/ENTER;
6.
If YES is pressed Display will show: ‘Shunt
Routine:-key in zone no (NO to exit)’;
7.
Press zone number (1-6) required. Display will
show ‘Z (No of zone) 1 2 3 - 0 (circuits)’ and the
Circuits that may shunted (excluded) will flash;
8.
Press circuit numbers that are to be shunted
(excluded). Display will indicate shunted circuits
with ‘s’ Press YES/ENTER;
9.
Display will show; ‘shunt Routine; - key in zone no
(NO to exit)’. Repeat steps 6 to 8 for other zones
and circuits if required;
10. Press NO. Display will show ‘leave via exit route’;
11. Exit sounder will sound. Leave via the designated
exit route and close the last exit;
12. When the sounder stops the system is Part Set to
partially guard the premises.
FAULT CONDITIONS
1. A Fault condition is indicated by the fault sounder
and a displayed message. The following faults
may occur;
2. Circuits are in alarm when attempting to set the
system. The affected circuits will be displayed
(Zone XX cct YY) and they must be corrected
before the system will set;
3. Departing from the exit route during the setting
procedure. The affected circuits will be displayed
(Zone XX cct YY) and they must be corrected
before the system will set;
4. Exceeding the time limit or not closing all exit route
devices if Timed Exit is used. The display will
show ‘Time-out Exit’ and the setting procedure
must be re-started;
5. If an incorrect code is entered wait 5 seconds then
re-enter the correct code.