![Tunstall CPA6 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/tunstall/cpa6/cpa6_installation-and-user-manual_1180084013.webp)
CPA6
496524 Issue A
13 of 16
CPA6
ENTER USER
NUMBER TO BE
PROGRAMMED
“KEY IN USER
CODE”
“YES/ENTER”
“Code X? 0000”
“YES/ENTER”
“Do you want the
User Routine?”
“Code X? YYYY”
“Do you want to
examine log?”
ENTER
ENGINEER
CODE
USER
ROUTINE
60
61
62
63
64
“NO”
The display awaits keypad information.
As keys are pressed, the display will show the code being set. When
this is correct, press the “YES/ENTER” key.
Registers User code x in the panel’s memory.
Selecting this User routine will enable the alarm system to be fully
tested and set/opened by the Engineer, without knowledge of any
user Code.
The commissioning routine will return to step 2.
If any errors have been made during programming, they can now be
rectified by “skipping” through the routine to the relevant point and
then amending data.
Alarm system may be fully tested and set by following simple display
and prompts.
Entry of the Code places the panel in the system “OPEN” (Day) mode.
STEP
KEYPAD
DISPLAY
KEYPAD
OPERATION
READOUT
OPERATION
Comments