background image

 

 

Owner Manual 

M600 

– 

MODIFIED SINE WAVE

 

M600-GD-0615-EN 

 

 

 

 

 

 

 

 

                                     2041-A, Leonard-de Vinci, Sainte-Julie (Quebec) Canada  J3E 1Z2                                

9

 

Tel : 

450.649.2470

  /  

1.877.964.2582

   Fax : 

1.888.855.9834

 

 
 

3.  SPECIFICATIONS 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. 

RECOMMENDATIONS 

 

1. 

The M600 only works with a 12 volt DC source. 

2. 

The inverter should always be OFF when starting the vehicle. 

3. 

If your consumption exceeds the inverter capacity, an overload protection will automatically turn it OFF. To restart the 
inverter, reduce your consumption. If the inverter doesn’t resume automatically, shut it and restart it manually using the 
ON/OFF switch located on the front panel. 

4. 

Stop using the inverter if the 12 volt power cord has been damaged. Have it repaired before using it again. 

5. 

This inverter could get very hot. Make sure there is no flammable materials near or around it.  

6. 

Keep the inverter away from liquids, snow or any other source of humidity. The electricity produced by the inverter can 
create an electric arc in presence of humidity and cause serious injuries or even death.  

7. 

If the inverter has been exposed to rain, moisture, or strong impact, have it inspected by a qualified technician before 
using it again.

 

8. 

We strongly recommend using a «pure sine wave» inverter for sophisticated electronic devices. 

9. 

Do not attempt any repair or modification on this product. If your inverter requires attention, contact your retailer. 

 

Model 

M600 

Type 

Power Inverter 

Grade 

Professional 

Part number 

TUN112003 

Electrical specifications 

 

Continuous output power 

600W 

Peak output power 

1200W 

Input voltage (nominal) 

12 VDC 

Operating input voltage 

10-15 VDC 

Output voltage 

120 VAC  +/- 3% 

Output frequency 

60 Hz 

Output wave form 

Modified sine wave 

DC efficiency (Peak) 

90% 

AC efficiency (Peak) 

90% 

General Specifications 

 

AC outputs 

2 x NEMA 5-15R 

Operating temperatures 

 -30° to 131°F 

Cooling fan(s) 

Thermostatic 

Construction 

Aluminium 

DC inputs 

1 meter cables w. lugs 

Unit dimensions (W x L x H) - English (in.) 

9,3 x 5,0 x 3,3 

Unit dimensions (W x L x H) - Metric (cm.) 

23,6 x 12,7 x 8,4 

Unit weight (Lbs / kg) 

4,0 / 1,8 

Warranty 

1 Year 

Отзывы: