background image

 
Quick troubleshooting Guide

 

TUN-QTSG-0519-EN_A3 
For power inverter models M1500 – M2000 – M2500 – M3000 

ANNEX 3

 

                        

 

Tel.: 

450.649.2470

  /  

1.877.964.2582

   Fax.: 

1.888.855.9834 

TUNDRAINVERTERS.COM

GENERAL INFORMATION  1-2 

 
 

LIMITATIONS

 

 
Electrical  codes  may  vary  depending  on  the  region  and  type  of  installation.  The  electrical  installation  must 
comply  with  local  and  national  standards,  and  must  be  carried  out  by  a  qualified  professional. 

Tundra 

International

 cannot be held liable for incidental or consequential damages or any other damage arising from 

the  use  of  its  products.  This  includes,  without  limitation,  damage  resulting  from  loss  of  use,  installation  or 
uninstallation costs, and any other problems. Specifications and features for all 

Tundra International

 products 

are subject to change without notice. 
 
 
 
 

PRESENTATION

 

 
The 

Tundra  International

  truck 

power  inverter

  system  is  a  battery-powered  electrical  system  providing  120 

volts  AC  power  similar  to  that  provided  by  conventional  power  grids.  When  coupled  to  a  battery  bank,  it 
produces  enough  power  for  the  driver  to  use  a  variety  of  electrical  and  electronic  devices.  Incorporating  the 
latest technologies, it is one of the most sophisticated and reliable in the industry, and will offer years of trouble-
free operation. 
 
 

 
 
 
 
Key features 
 

- State-of-the-art microprocessor 
- High-capacity components for a superior service life 

Multidata LCD display

 to track energy consumption and resolve problems 

- Ultralight one-piece design that withstands strain, vibrations and impacts 
- Aeronautical-grade assembly 

 
Key benefits 

 

- Outstanding efficiency and ultra-precise performance levels at all times 
- Extends the life cycle of the truck’s electrical charging and starting systems 
- Lowest cost of ownership – up to 2½ times less than the competition 

 
 

 
 
 

 
 
 

4

Содержание M1500

Страница 1: ...rnational No liability can be accepted for any inaccuracies or omissions in this publication although every possible care has been taken to make it as complete and accurate as possible The right is reserved to make changes at any time without prior notice and without incurring an obligation to make such changes applicable to previously manufactured products All information contained in this public...

Страница 2: ...EST LOCATION 2 5 VALIDATING YOUR LOCATION CHOICE 2 5 FLOOR ADAPTERS PILOT HOLES 2 6 FLOOR ADAPTERS HOLE SAW DRILLING 2 7 FLOOR ADAPTERS INSTALLATION 2 8 POWER INVERTER INSTALLATION 2 9 2 10 CONNECTING THE 12 V CABLES TO THE POWER INVERTER 2 10 2 11 GROUNDING VERIFICATION 2 12 GROUNDING PROCEDURE if required 2 13 MULTIDATA LCD MONITOR BEST LOCATION 2 13 MULTIDATA LCD MONITOR RECESSED INSTALLATION 2...

Страница 3: ...tion and to avoid costly mistakes be sure to read the instructions thoroughly so as to familiarize yourself with the procedures before starting the work Make sure your work area is clean Always use the specified tools Using substitutes may adversely affect the results and the safety of the user SAFETY FIRST TO REDUCE THE RISK OF ELECTRIC SHOCK FIRE OR INJURY PLEASE TAKE NOTE OF THE FOLLOWING RECOM...

Страница 4: ...out notice PRESENTATION The Tundra International truck power inverter system is a battery powered electrical system providing 120 volts AC power similar to that provided by conventional power grids When coupled to a battery bank it produces enough power for the driver to use a variety of electrical and electronic devices Incorporating the latest technologies it is one of the most sophisticated and...

Страница 5: ... LCD monitor 3 Multidata LCD monitor cable 4 Monitor surface mount kit 5 Rubber insulators 6 DC input screws 7 Instruction manual CM Installation Kit 1 Negative battery cable 2 Positive battery cable 3 Positive cable for fuse holder 4 Plastic ties 5 Floor adapters strain reliefs 6 Drilling template 7 Steel clamps 8 Screws for steel clamps 9 Plastic loom 10 Fuse holder 11 Fuse The length and capaci...

Страница 6: ...DRAINVERTERS COM INSTALLATION INSIDE THE CAB 2 1 DANGER HIGH VOLTAGE A power inverter produces an electrical current similar to that produced by conventional power grids This electrical current has the potential to kill or injure anyone nearby For safety reasons a power inverter must always be installed inside the cab in the luggage compartment under the bed 6 ...

Страница 7: ...Guide TUN QTSG 0519 EN_A3 For power inverter models M1500 M2000 M2500 M3000 ANNEX 3 Tel 450 649 2470 1 877 964 2582 Fax 1 888 855 9834 TUNDRAINVERTERS COM INSTALLATION INSIDE THE CAB 2 2 THINK QUALITY QUALITY WORK RESULTS 7 ...

Страница 8: ...877 964 2582 Fax 1 888 855 9834 TUNDRAINVERTERS COM INSTALLATION INSIDE THE CAB 2 3 WHERE TO INSTALL THE INVERTER The power inverter MUST be installed inside the cab in the luggage compartment under the bed 1 Flat on the floor Or 2 On a vertical steel wall NEVER IN A CABINET NEVER IN THE BOOTS STORAGE NEVER BEHIND THE SEAT 8 ...

Страница 9: ...N 1 Compared to other brands Tundra International power inverters produce very little heat A minimum clearance of 7 cm 2 at the ends is sufficient A power inverter should take up as little space as possible to favor the driver If the power inverter is installed on the floor make sure it is as close as possible to a wall A protective plate could be installed over it so that this space can serve as ...

Страница 10: ...er inverter VALIDATING YOUR LOCATION CHOICE Observe the following 5 criteria 1 The power inverter mounting holes must not damage wires hoses or other parts under the cab 2 Floor adapter holes must not damage wires hoses or other parts under the cab 3 Do not drill into the cab cross member 4 The cables should be kept close to the power inverter but not too close They need to be easily installed on ...

Страница 11: ...0 M2000 M2500 M3000 ANNEX 3 Tel 450 649 2470 1 877 964 2582 Fax 1 888 855 9834 TUNDRAINVERTERS COM INSTALLATION INSIDE THE CAB 2 6 FLOOR ADAPTERS PILOT HOLES 1 Using the template included in the CM installation kit drill two 1 8 pilot holes to validate your choice of location 11 ...

Страница 12: ...d drill the holes for the floor adapters based on the chart below HOLE SAW CHART hole size depends on CM installation kit to be installed MODEL CM1512 CM1510 CM1508 CM1506 MODEL CM2012 CM2010 CM2008 CM2006 CM2512 CM2510 CM2508 CM2506 CM3012 CM3010 CM3008 CM3006 Drill the carpet with a hole saw punch that s the same size as the cables and then drill the floor from underneath with the required hole ...

Страница 13: ...h the floor 3 Lift the carpet and install its nut by hand 4 Tighten the nut securely with adjustable pliers Do not overly tighten 5 Repeat steps 1 to 4 for the second cable 6 Fold the carpet over the cables The cables should intersect between the floor and the DC inputs of the power inverter Please note this when inserting cables through the floor This will allow attaching both cables together and...

Страница 14: ...ly install the cables to the DC inputs of the power inverter to validate its position Relocate the power inverter if required 3 Using the power inverter as a template mark the location of the 4 required mounting holes 4 Remove the power inverter and drill the 4 holes of 9 32 inches 5 Secure the power inverter firmly to the vehicle using the included bolts and self locking nuts Make sure the power ...

Страница 15: ...nverter Tighten the 4 nuts gradually in crossed sequence at the corners of the power inverter for a uniform clamping force If mounting on a mat or a rubber surface do not over tighten the nuts so as to avoid power inverter distortion CONNECTING THE 12 V CABLES TO THE POWER INVERTER 1 Insert the rubber insulators on the cables with the correct polarity RED POSITIVE BLACK NEGATIVE Gently heat the in...

Страница 16: ...e rubber insulators on each of the cables to protect the inverter s DC inputs 4 Adjust the cables so that they do not create pressure on the inverter s DC inputs 5 Underneath the cab tighten the floor adapter caps by hand to secure the cables in place Do not use pliers as they may damage them 6 Install the plastic loom over both cable sections Use the loom included in the CM installation kit 7 Usi...

Страница 17: ... connecting its housing to the vehicle chassis so that the power inverter can more quickly detect any trace of voltage leakage resulting from a damaged 120 V device or extension or from a positive wire coming into contact with the power inverter or with the vehicle chassis If the power inverter is attached to a metal plate in the cabin its grounding is probably adequate We recommend checking it by...

Страница 18: ...he back panel of the power inverter to your grounding point of contact with the chassis 3 Confirm your installation with a 12 V test lamp using the GROUNDING VERIFICATION procedure on page 2 12 Do not connect the GROUND terminal to the negative input terminal of the power inverter MULTIDATA LCD MONITOR BEST LOCATION Determine the best location to install the multidata LCD monitor according to the ...

Страница 19: ...erter route the 20 ft 6 m cable from the multidata LCD monitor to the desired location 2 Make sure the monitor cable does not come into contact with sharp edges that could damage it 3 If necessary use self adhesive retainers or plastic ties 4 Using the template included with the power inverter drill a hole to insert the rear embossed part of the multidata LCD monitor 5 Connect the monitor cable to...

Страница 20: ...d We suggest validating your cutting measurements more than once so as to minimize the chances of damaging the panel Moreover we suggest using masking tape to avoid scratches during cutting MULTIDATA LCD MONITOR SURFACE INSTALLATION 1 From the front panel of the power inverter route the 20 ft 6 m cable from the multidata LCD monitor to the desired location 2 Make sure the monitor cable does not co...

Страница 21: ...HE CAB 2 16 MULTIDATA LCD MONITOR SURFACE INSTALLATION con d 3 Release the two parts of the monitor surface mount kit included 4 Insert the cable into the opening of the bottom cover part 1 and secure the cover to the desired surface 5 Attach Part 2 to Part 1 by pressing firmly 6 Connect the cable to the multidata LCD monitor 7 Install the multidata LCD monitor with the included screws 4 7 5 3 21 ...

Страница 22: ...m included in the CM installation kit from one end to the other This will help protect them from road debris and allow them to maintain their integrity much longer 2 Every 12 attach the battery cables together using the included plastic ties from one end to the other This will help to protect them DC cables can produce magnetic fields strong enough to interfere with radio communication devices Tyi...

Страница 23: ...s to the battery box is an important step 1 Never suspend the power inverter cables to the truck s cables or hoses 2 Beware of exhaust pipes Their heat could damage the cables 3 Pay attention to metal parts with sharp edges they could damage the cables 1 Route the power inverter cables to the battery box Fasten them securely to the chassis of the cab using the metallic clips and self drilling scre...

Страница 24: ...s loop must be located near the battery box If the loop is made at the rear of the cab it must be larger so as to accommodate the greater amplitude of cab suspension movement at the rear 3 Insert the cables into one of the rear openings of the battery box 4 Secure the power inverter cables to the surrounding cables with plastic ties to protect them from vibration Do not hesitate to use several pla...

Страница 25: ... CM installation kit in accordance with the upper leg s direction of rotation 4 On one of the terminals install the positive cable red from the power inverter overlap the washer and nut and tighten the nut to 10 lb ft 5 On the other terminal install the 12 positive cable red included in the CM installation kit overlap the washer and nut and tighten the nut to 10 lb ft 6 Install the protective cove...

Страница 26: ...ation of the power inverter Ignoring our instructions may result in the inverter not operating at full power 1 The power inverter cables must be connected to the batteries in order to distribute the charge evenly between the four batteries A The positive and negative cables must be as far apart as possible from one another B Maximum of three terminals per battery post C The power inverter cables m...

Страница 27: ... BATTERIES SECURING CABLES To insure your safety 1 The power inverter cables must be attached with plastic ties to the other cables on the top of the batteries 2 If there is excess cable do not cut it It must be wound on the top of the batteries and also attached to the other cables It is preferable to never attach the fuse holder to a battery box wall The safest location is on top of the batterie...

Отзывы: