Table 3. Default Parameter Settings

Function

Parameter

Default Setting

Weighing Unit

C01

1

Decimal Setting

C02

0

Graduation Setting

C03

1

Maximum Capacity

C04

100000

Zero Calibration

C05

0

Calibration

C06

0

Restore Default

C07

0

Warning Tone

C08

1

Automatic Power Off

C09

0

Power Saving Mode

C10

0

Hold Function

C11

0

Unit Conversion

C12

1

Upper Limit Alarm

C13

000000

Lower Limit Alarm

C14

000000

Inner Code Display

C15

Set Date

C16

Set Time

C17

Communication Setting

C18

1

Baud Rate

C19

3 (9600)

Manual Zero Range

C20

10

Initial Zero Range

C21

10

Zero Tracking

C22

1.0

Zero Tracking Time

C23

3

Overload Range

C24

9

Negative Display

C25

10

Standstill Time

C26

1

Standstill Range

C27

2

Digital Filter

C28

3

Noise Filter

C29

2

Print Time and Date

C30

0

Analog Output Setting

C31

1

Relay Output Setting

C33

1

Multi-connection add.

C34

0

Wireless Communication

C35

6

Gravity of Calibration Location

C36

9.7936

Gravity of Destination

C37

9.7936

Print Mode

C41

0

Print Carriage Return

C42

2

Space Print

C43

0

Date Print

C44

1

Time Print

C45

1

LED Display Brightness

C49

4

- 13 -

Содержание T909

Страница 1: ...T909 User s Manual...

Страница 2: ...PREPARATION SETUP FEATURES SPECIFICATIONS POWERSUPPLY DISPLAYANDKEYDESCRIPTION OPERATINGINSTRUCTIONS CALIBRATIONPROCEDURE INDICATORPARAMETERSETTINGS CONNECTORS TROUBLESHOOTING TABLEOFCONTENTS 1 1 2 3...

Страница 3: ...et Disconnect power before servicing unit All operators MUST discharge themselves before servicing unit Always pull the plug not the cord when disconnecting from the outlet DO NOT use if the power cor...

Страница 4: ...vity based on different geographical locations RS232 output Optional dual load cell ports Main Features Technical Parameters Accuracy class Zero stability error Span stability error Sensitivity intern...

Страница 5: ...e with wirings Battery If you have an indicator with the rechargeable battery option please charge the internal battery fully before first time use A 110 to 220V AC adapter should be provided with you...

Страница 6: ...N when the weight value is being held UNDER ON when the weight is below the min preset value ACCEPT ON when the weight is within the acceptable range OVER ON when the weight is over the max preset val...

Страница 7: ...sh to see the current change in weight not the total weight When the indicator is in gross mode gross light is shown pressing the TARE key will Tare the current weight on the scale and enter the net m...

Страница 8: ...pressed again 3 Average Hold Used for weighing animal the indicator will display the average weight sampled from 3 seconds Add livestock to scale and press HOLD Indicator screen will show LOC for 3 se...

Страница 9: ...this scale by using UNITS cursor right and TARE and ZERO to move the values down and up The C4 channel is to move the used to enter in the max capacity of the scale Make sure this doesn t exceed the...

Страница 10: ...calibration weight you have on the empty scale and press PRINT enter 11 The scale will count down from 10 to 0 Once 0 has been reached the display will show he screen will show CALEnd 12 Then follow...

Страница 11: ...This will allow access to all C01 and up settings If the seal switch is ON then only C08 and up can be accessed by the user If you break the official seal by opening the back of the indicator to acces...

Страница 12: ...thin the max capacity Lower Limit Alarm Set lower limit within the max capacity Inner Code Display check the inner code raw data Set Date Set date from left to right year month day Set Time Set the ti...

Страница 13: ...Display 0 9d 10 10 max capacity 20 20 max capacity 50 50 max capacity 100 100 max capacity Standstill Time 0 quick 1 medium 2 slow Standstill Range 1 1d d division 2 2d 5 5d 10 10d Digital Filter for...

Страница 14: ...Calibrate Current Relay Output Setting Zero Setting Gravity of Calibration Location Gravity of Destination Version No Print Mode Print Carriage Return Space Print Date Print Time Print LED Display Br...

Страница 15: ...Set Time C17 Communication Setting C18 1 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracking C22 1 0 Zero Tracking Time C23 3 Overload Range C24 9 Negative Display C2...

Страница 16: ...IGURE 2 QUICK DISCONNECT CONNECTION DIAGRAM Hardwire Using Inner Terminal Block Connection Note Make sure you follow all the anti static rules to avoid damage to your indicator Excitation voltage 5VDC...

Страница 17: ...s 8 data bits 1 stop bits No parity No handshaking 2 RS 232 Connection DB9 9 pin Connector Table 4 Wiring Color Code Signal Name Description Exe EX Positive excitation voltage to load cell IN SIG Posi...

Страница 18: ...0 1 0 1 1 0 1 1 0 0 2 0 0 0 1 1 Bits3 4 1 0 1 0 Decimal point position XXXXXX0 XXXXXXX XXXXX X XXXX XX XXX XXX Division X1 X2 State B BitsS function Bits0 gross 0 net 1 Bits1 Symbol positive 0 negati...

Страница 19: ...mode the indicator can receive ASCII commands as listed below Command Name T Tare Z Zero P Print R G W N W C Kg lb G G W Function Save and clear tare Zero gross weight Print the weight Read gross weig...

Страница 20: ...18 5 Print to Adhesive Label Printers C18 5 C18 6 Printing formats Date Time Net Tare Gross 05 01 2017 11 30 52 25 6lb 10 3lb 35 9lb Date Time XX XX XX yy mm dd XX XX XX hh mm ss NET TARE GROSS 6 00kg...

Страница 21: ...nected to the load cell and or the junction box if one is used UUUUUU 1 Overload 2 Cables are not connected properly 3 Load cell is defective 1 Reduce the weight 2 Check load cell connection 3 Inspect...

Страница 22: ...ded Recalibrate 5 If none of the above works one or more load cells may be defective Err1 No weight was used during calibration or the weight used was above the max capacity Use correct weight within...

Страница 23: ...sure the feet are attached Press the ZERO button to make the 0 to 1 C5 1 appears Press the PRINT button CAL 10 to CAL 9 to CAL 1 0 should appear 0 is a good sign Press the PRINT button C06 should appe...

Отзывы: