1.     Press 

PRINT

 

enter

 to continue. The display will now show 

C06

.

2.     Press 

PRINT enter

 to access the C06 channel. The display will show 

3.     The C6 channel is used to calibrate the scale with a known weight. Press 

ZERO       

to set the 

        value of C6 to   

C6     2

 

 . Press 

PRINT enter

. The display will flash 

SPAN

, and then 

        show 

LnE 2

 

4.     Press 

ZERO

      to enter the number of weights you want to use (2-7); the more you use, the 

        more accurate the calibration will be. (an example of 2 will be used).
5.     Press 

PRINT enter

 to set your value. The screen will flash [ 

dbno01

 

] then [ 

000100

]

6.     Enter the lowest calibration weight value you will use (at least 10% of max capacity you set 
        in C04) by using 

UNITS

      to move the cursor right and 

TARE    

  and 

ZERO

     move the values 

        down and up.
7.     Place the calibration weight you have on the empty scale and press 

PRINT enter

 .

8.     The scale will count down from 10 to 0. Once 0 has been reached, the display will show the 
        screen will flash [ 

dbno02

 

] then [ 

000200

 

].

9.     Enter the next calibration weight value you will use by using 

UNITS

      to move the cursor right, 

        and 

TARE

     and 

ZERO

     move the values down and up .

10.   Place the calibration weight you have on the empty scale and press 

PRINT enter

 .

11.   The scale will count down from 10 to 0. Once 0 has been reached, the display will  show he 
        screen will show [ 

CALEnd

 

].

12.   Then follow steps 26-31 on the single point calibration instructions.

23.  Enter the calibration weight value you will use (at least 10% of max capacity you set in C04 by 

using 

UNITS

 

 

to move the cursor right, and 

TARE

and 

ZERO

move the values down

and up.)

24.  Place the calibration weight you have on the empty scale and press 

PRINT enter

.

25.  The scale will count down from 10 to 0. Once 0 has been reached, the display will show

CALEnD .

26.

.

Press 

PRINT

27. Press 

HOLD esc 

to save and exit the setup menu.

28. The scale has now been calibrated. The display will show the value of the calibration weight 

on the scale.

29. If the scale does not show the value of the calibration weight, check that the feet on the platform 

are not screwed in too tightly, and verify that the platform is level.

30. Unload the scale; the display should read 

000000.

31. If the scale does not display 000000, check that the feet on the platform are not screwed in too 

tightly, and verify that the platform is level.

 to set the value. The display will now show 

C07

.

enter

To Calibrate using only multiple calibration weights (Linear Calibration)

C6  0

[

].

[

[  

.

- 8 -

Содержание T909

Страница 1: ...T909 User s Manual...

Страница 2: ...PREPARATION SETUP FEATURES SPECIFICATIONS POWERSUPPLY DISPLAYANDKEYDESCRIPTION OPERATINGINSTRUCTIONS CALIBRATIONPROCEDURE INDICATORPARAMETERSETTINGS CONNECTORS TROUBLESHOOTING TABLEOFCONTENTS 1 1 2 3...

Страница 3: ...et Disconnect power before servicing unit All operators MUST discharge themselves before servicing unit Always pull the plug not the cord when disconnecting from the outlet DO NOT use if the power cor...

Страница 4: ...vity based on different geographical locations RS232 output Optional dual load cell ports Main Features Technical Parameters Accuracy class Zero stability error Span stability error Sensitivity intern...

Страница 5: ...e with wirings Battery If you have an indicator with the rechargeable battery option please charge the internal battery fully before first time use A 110 to 220V AC adapter should be provided with you...

Страница 6: ...N when the weight value is being held UNDER ON when the weight is below the min preset value ACCEPT ON when the weight is within the acceptable range OVER ON when the weight is over the max preset val...

Страница 7: ...sh to see the current change in weight not the total weight When the indicator is in gross mode gross light is shown pressing the TARE key will Tare the current weight on the scale and enter the net m...

Страница 8: ...pressed again 3 Average Hold Used for weighing animal the indicator will display the average weight sampled from 3 seconds Add livestock to scale and press HOLD Indicator screen will show LOC for 3 se...

Страница 9: ...this scale by using UNITS cursor right and TARE and ZERO to move the values down and up The C4 channel is to move the used to enter in the max capacity of the scale Make sure this doesn t exceed the...

Страница 10: ...calibration weight you have on the empty scale and press PRINT enter 11 The scale will count down from 10 to 0 Once 0 has been reached the display will show he screen will show CALEnd 12 Then follow...

Страница 11: ...This will allow access to all C01 and up settings If the seal switch is ON then only C08 and up can be accessed by the user If you break the official seal by opening the back of the indicator to acces...

Страница 12: ...thin the max capacity Lower Limit Alarm Set lower limit within the max capacity Inner Code Display check the inner code raw data Set Date Set date from left to right year month day Set Time Set the ti...

Страница 13: ...Display 0 9d 10 10 max capacity 20 20 max capacity 50 50 max capacity 100 100 max capacity Standstill Time 0 quick 1 medium 2 slow Standstill Range 1 1d d division 2 2d 5 5d 10 10d Digital Filter for...

Страница 14: ...Calibrate Current Relay Output Setting Zero Setting Gravity of Calibration Location Gravity of Destination Version No Print Mode Print Carriage Return Space Print Date Print Time Print LED Display Br...

Страница 15: ...Set Time C17 Communication Setting C18 1 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracking C22 1 0 Zero Tracking Time C23 3 Overload Range C24 9 Negative Display C2...

Страница 16: ...IGURE 2 QUICK DISCONNECT CONNECTION DIAGRAM Hardwire Using Inner Terminal Block Connection Note Make sure you follow all the anti static rules to avoid damage to your indicator Excitation voltage 5VDC...

Страница 17: ...s 8 data bits 1 stop bits No parity No handshaking 2 RS 232 Connection DB9 9 pin Connector Table 4 Wiring Color Code Signal Name Description Exe EX Positive excitation voltage to load cell IN SIG Posi...

Страница 18: ...0 1 0 1 1 0 1 1 0 0 2 0 0 0 1 1 Bits3 4 1 0 1 0 Decimal point position XXXXXX0 XXXXXXX XXXXX X XXXX XX XXX XXX Division X1 X2 State B BitsS function Bits0 gross 0 net 1 Bits1 Symbol positive 0 negati...

Страница 19: ...mode the indicator can receive ASCII commands as listed below Command Name T Tare Z Zero P Print R G W N W C Kg lb G G W Function Save and clear tare Zero gross weight Print the weight Read gross weig...

Страница 20: ...18 5 Print to Adhesive Label Printers C18 5 C18 6 Printing formats Date Time Net Tare Gross 05 01 2017 11 30 52 25 6lb 10 3lb 35 9lb Date Time XX XX XX yy mm dd XX XX XX hh mm ss NET TARE GROSS 6 00kg...

Страница 21: ...nected to the load cell and or the junction box if one is used UUUUUU 1 Overload 2 Cables are not connected properly 3 Load cell is defective 1 Reduce the weight 2 Check load cell connection 3 Inspect...

Страница 22: ...ded Recalibrate 5 If none of the above works one or more load cells may be defective Err1 No weight was used during calibration or the weight used was above the max capacity Use correct weight within...

Страница 23: ...sure the feet are attached Press the ZERO button to make the 0 to 1 C5 1 appears Press the PRINT button CAL 10 to CAL 9 to CAL 1 0 should appear 0 is a good sign Press the PRINT button C06 should appe...