Tufner 8000 REPEL Скачать руководство пользователя страница 11

8000 REPEL

 Digital Weight Indicator User Manual 

11 

the sample size. Repeat Step #4 with the new sample size.  

NOTE:

 

If the indicator continues to display “Lo” even after sampling 1

00 pieces, the 

unit weight of the items you wish to count is too light for your scale to process ac-
curately. 

5. To exit the piece count mode, press the UNITS key.

NOTE:

 The APW will NOT remain in scale memory when you exit piece counting

mode.

4.4 Peak Hold Mode 

IMPORTANT NOTE:

 The peak hold function cannot be used in commercial (NTEP) appli-

cations.

 

 

This mode of operation is enabled by setting F30 to “5” in the Setup Menu and 

F35 to 

“3” in the User Menu (see separate installer’s guide for more information). 

This mode 

is used to indicate and hold the peak weight recorded during a specific process. The 
most common application is testing the breaking point of a part or assembly. The 

8000 

REPEL

 records both positive and negative peak weights. 

1. Push the UNITS key to active peak hold mode; the 

“P” annunciator turns ON.

2. Apply force to the piece 

 the display indicates and holds the peak force ap-

plied.

3. To toggle between positive and negative peak weights, use the NET/GROSS

key.

4. To reset both peak values to zero, press the ZERO key.

5. To exit peak hold mode, press the UNITS key again; 

the “P” annunciator turns

OFF.

4.5 Accumulation (Totaling) 

This mode of operation is enabled by setting F30 to “1” in the Setup 

Menu

 

(see sepa-

rate installer’s guide for more information).

 

The mode allows you to add weighments 

together to obtain a total weight. When a tare weight is active, the net weight is added 
automatically.  

1. Load the system with the weight that is to be added.

2. Press the PRINT key to add the current load to the weight accumulator.

3.

The display briefly shows the message “ADDED” and then automatically returns

to the weighing mode.

Содержание 8000 REPEL

Страница 1: ...8000 REPEL Digital Weight Indicator User Manual V1 6 TUFNER WEIGHING SYSTEMS 9030 Bridgeport Place Rancho Cucamonga CA 91730 Main 800 810 2965 Fax 888 502 8997...

Страница 2: ...2 4 Operation TI 500 RFTM 4 2 5 Replacing the batteries TI 500 RFTM 5 2 6 Optional rechargeable battery information 5 3 DISPLAY KEYPAD DETAILS 7 4 ADVANCED OPERATION 9 4 1 Hold operation 9 4 2 NET we...

Страница 3: ...ause damage Routine maintenance Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions should not be used especially on the display window The outside of the product may be wiped d...

Страница 4: ...hing it is necessary to check if the scale is unloaded and indicating zero weight in the desired unit of measure for example lb for pounds If the indicator is not displaying the desired unit of measur...

Страница 5: ...eries TI 500 RFTM An optional cylindrical battery holder is available which requires 4 C cell alkaline bat teries 1 Turn the TI 500 RFTM OFF Press the RED button 2 Locate the metal battery cylinder 3...

Страница 6: ...charged the Low Battery Indicator will start blinking in the lower left hand corner of the display The indicator may be used for an additional 2 minutes before it automatically powers down It is imper...

Страница 7: ...he sys tem P Indicates that the indicator is in PEAK HOLD mode lb Indicates that the unit of the displayed weight is in pounds kg Indicates that the unit of the displayed weight is in kilograms g Indi...

Страница 8: ...Gross weight 2 The scale is not in motion 3 The scale is not in overload see error codes Net Gross This key toggles the indicator between Gross weight and Net weight provided that a Tare weight has fi...

Страница 9: ...essed again If the weight of the object on the scale changes by the F36 setting e g 10 then the sale unlocks the held reading and relocks onto the new weight This occurs during increasing weight value...

Страница 10: ...total weight of the sample is too light accuracy cannot be guaranteed You will get an error message but piece counting will still be allowed This indicator does not retain the piece weight when powere...

Страница 11: ...esting the breaking point of a part or assembly The 8000 REPEL records both positive and negative peak weights 1 Push the UNITS key to active peak hold mode the P annunciator turns ON 2 Apply force to...

Страница 12: ...n the total is reset to zero but not printed If no key is pressed during this period then the subtotal stays in memory and the system returns to the weighing mode 4 6 Printer If the weighing system ha...

Страница 13: ...of the flashing digit 10 After entering the exact value press the NET GROSS key to save the value The screen displays n _xx where xx is the current minute e g 55 One digit will be flashing 11 Use the...

Страница 14: ...rms then this mode re quires an optional digital I O board Use the A1 25 menu to set the logic of the out puts Optional Digital I O 3 out 1 in Logic level only i e external relays are required to driv...

Страница 15: ...of the flashing digit 5 After entering the exact value press the NET GROSS key to save the value The screen displays SET briefly The high low weight values are activated and the display returns to the...

Страница 16: ...not found ensure that it is powered ON or move it closer to the digital in dicator WIRELESS SYSTEMS ONLY TI 500 RFTM 1 batteries have been depleted and need to be replaced WIRELESS SYSTEMS ONLY TI 50...

Страница 17: ...olycarbonate enclosure rated for IP69 1 0 7 digit LCD w LED backlight optional reverse LCD also available Operating temperature 4 F to 104 F 20 C to 40 C Internal connection port for optional printer...

Страница 18: ...and platform or within platform with multiple load cells cabled configuration only Load cell damaged on platform Internal fault with indicator call Tufner Tech Support Scale turns off on its own The i...

Страница 19: ......

Отзывы: