background image

- 38 -

LIMITED WARRANTY

LIMITED WARRANTY

The warranty below has been drafted to comply with Federal Law applicable
to products manufactured after July 4, 1975.  This warranty is extended
only to the original purchaser/consumer (or dealer non-consumer who
does not buy for resale).

Tuffcare

®

warrants that it’s Rhino Series patient lifters will be free from

defective workmanship and materials for a period of three (3) years following
the date of original manufacture with the following exceptions: All welds
are warranted for the life of the lift.  Electronics on the lifters are warranted
for one (1) year.  The warranty period commences on the original manufacture
date.  If within such warranty period any such product proven to Tuffcare

®

satisfaction to be defective, such product will be repaired or replaced at
Tuffcare

®

option.

Tuffcare

®

sole obligation and your exclusive remedy under this warranty

shall be limited to such repair and/or replacement. This warranty does not
include any labor charges incurred in replacement parts installation.
Freight charges to the factory are at the expense of the consumer or seller.
Return freight charges will be prepaid by Tuffcare

®

. For warranty service,

please contact the authorized dealer from whom you purchased your
Tuffcare

®

products. In the event that you do not receive satisfactory warranty

service, please write directly to: Tuffcare

®

: 4977 La Palma Ave, Anaheim,

California, 92807. DO NOT RETURN PRODUCTS WITHOUT PRIOR
AUTHORIZATION.

LIMITATIONS AND EXCLUSIONS: The foregoing warranty shall not
apply to products subjected to negligence, abuse, misuse, improper operation,
improper maintenance, improper storage or damages beyond Tuffcare

®

control. The evaluation will be solely determined by Tuffcare

®

. The warranty

shall not apply to problems arising from normal wear, or failure to follow
instructions, or if parts are not manufactured by Tuffcare

®

, or do not comply

with original equipment specifications that are added to Tuffcare

®

product.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE AND SHALL NOT EXTEND BEYOND THE
DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN.
TUFFCARE

®

SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR

INCIDENTAL
DAMAGES WHATSOEVER.

This warranty gives you specific rights and you may also have other legal
rights which vary from state to state. Some states do not allow the exclusion
or limitations of incidental or consequential damage, or limitation on how
long an implied warranty

- 37 -

MAINTENANCE

MAINTENANCE

CLEANING THE LIFT

•  The lift can be cleaned with non-abrasive cleaners.

Make sure that the wheels are free of hair, lint and
other debris.

DETECTING WEAR AND DAMAGE

• Check monthly that all screws are tight and have not 

loosened.

• Check monthly for damaged or exposed wires on the

electrical components.

• Inspect monthly for signs of cracking, fraying, or any

deterioration.

• Contact your equipment provider for replacement of  

any defective parts immediately and ensure that the

lift is not used until repair job is completed.

LUBRICATING THE LIFT

•  A light grease lubricant may be applied to the ball

bearing and swivel of the casters every three months.

PERFORMING REGULAR MAINTENANCE

•  Regular maintenance of the lift and accessories is

required to ensure proper operation.  The casters and 

axle bolts are also required to be checked for proper

tightness.

Содержание Rhino P420

Страница 1: ...ra at ti in ng g M Ma an nu ua al l TUFFCARE INC ALL RIGHTS RESERVED RHINO ELECTRIC LIFT_V2 3TW W W W T U F F C A R E C O M ATTENTION Before using this Medical Device read this manual If you are unabl...

Страница 2: ...t from and toAutomobile 33 34 Lift Sling Type Reference 35 36 Maintenance 37 Limited Warranty 38 1 S P E C I F I C AT I O N S S P E C I F I C AT I O N S Height at Sling Hook up MAX 81 inches Height at...

Страница 3: ...Pack M Push Handle Bar PRODUCT DIAGRAM PRODUCT DIAGRAM A B C D E L G H I J K M F SEMI ELECTRIC PATIENT LIFTER P420 A Lift Arm B Attachment Sling Cradle C Up Down Actuator D Hand Pendant E Mast F Dual...

Страница 4: ...and has a grounding plug A temporary adapter may be used to connect this plug to a two pole receptacle if a properly grounded outlet is not available The temporary adapter should be used only until a...

Страница 5: ...secured During transfer with the patient suspended in a sling attached to the lifter DO NOT roll the base over uneven surfaces that would create an imbalance of the patient lifter and could cause the...

Страница 6: ...ecure the bolts and nuts Note The two longer bolts are used on side by side upper lower holes short one is used on the middle 4 Check and tighten all hardware BEFORE use 10 ATTACH THE UP DOWN ACTUATOR...

Страница 7: ...st small flat washer that was on top of the actuator through bolt 3 Install the bolt through the hole in the mast make sure the 3 included washers are lined up like the diagram 4 Place the small flat...

Страница 8: ...TROL UNIT ON THE MOUNTING BRACKET 1 Temporarily remove the controller setting screw from the mounting plate 2 Align the controller to the mounting plate at about a 5 degree angle 3 Make sure the 2 gro...

Страница 9: ...the controller at about a 5 degree angle 3 While holding onto the lever latch inside the handle move the battery pack parallel to the controller 4 Make sure the latch plate is lifted up and set over...

Страница 10: ...p of the battery against the mounting bracket until there is an audible click See more details on pages 15 16 for Attaching the Battery Pack onto the Control Unit 2 Make sure the red emergency button...

Страница 11: ...meter stops flashing and the LED turns from red to green Now the battery meter will indicate a full gauge when all the bars light up At this time the charger utilizes a slow charging Absorption Charge...

Страница 12: ...Powered On Red button pushed in Power Off NOTE When emergency button is pressed down the circuit is off and the unit will not function or charge 22 ACTIVATING A MECHANICAL EMERGENCY RELEASE EMERGENCY...

Страница 13: ...is assessed by a qualified professional Thoroughly read and fully understand the instructions in this Owner s Manual 3 ALWAYS keep hands and fingers clear of moving parts to avoid injury Individuals t...

Страница 14: ...TUFFCARE slings are made specifically for use with TUFFCARE floor type patient lifter Otherwise injury or damage may occur The legs of the patient lifter MUST be in the maximum open position for opti...

Страница 15: ...cradle is directly over the patient Lower the top bar and attach the loops on the sling to the hooks of the cradle 28 4 Elevate the patient into a upright position by raising the head of the bed or b...

Страница 16: ...NG PATIENT TO BED 1 Raise the lifter until the patient s buttocks are lifted above the mattress If the patient can not be lifted above the bed try to lower the bed height Do not push or pull patient o...

Страница 17: ...g make sure the pillows are beneath the patient s head 31 TRANSFERRING PATIENT FROM WHEELCHAIR 1 Secure the wheelchair from rolling back by engaging both wheel locks on the wheelchair 2 Lean patient f...

Страница 18: ...ached The lifter can be disassembled and placed in a car trunk second assistant 33 TRANSFER FROM AUTOMOBILE 1 Park the automobile on a flat smooth surface Open the car door all the way 2 Set a folded...

Страница 19: ...ng with preventing the patient from sliding in the sling our Tuffcare Rhino slings are universal and will accommodate any 2 4 or 6 point spreader bars from other suppliers 35 Model Size A B C Recommen...

Страница 20: ...ance improper storage or damages beyond Tuffcare control The evaluation will be solely determined by Tuffcare The warranty shall not apply to problems arising from normal wear or failure to follow ins...

Отзывы: