10
tank with the amount and liquid stated earlier.
C. Checking of bench lever functioning
Check rotation release-locking lever is working properly regularly. In the event of the
lever not locking correctly, loosen #55 grub screw, tighten #56 nut and fasten #55 grub
screw again. Make sure that with the bench lever in right position, #26 rotating arm
which supports the bow can rotate freely.