background image

  

PCB ASSY CNTL – (44115-0810) continued/.....

 

 

Part No. 

Position 

Description 

22575-0062 

HEADER 10 WAY (2X5) STR  

PJ4,104 

22575-0064 

HEADER 26 WAY (2X13) STR  

PJ8,108 

23185-0000 

RES ZERO OHM 

LK2,7,8,102,107,108  

23189-0560 

RES 56RJ 1W6 500PPM TYPE PR37 

R2,102  

23190-1100 

RES 100RJ 2W5 500PPM TYPE PR52 

R15,115 

23202-0220 

RES 22R0F W25 MF 50PPM 

R84,184 

23202-1470 

RES 470RF W25 MF 50PPM 

R55,155 

23202-1750 

RES 750RF W25 MF 50PPM 

R12,22,112,122  

23202-2100 

RES 1K00F W25 MF 50PPM 

R3,17,39,57,61,68,95,96,103,117,139, 
157,161,168,195,196  

23202-2150 

RES 1K50F W25 MF 50PPM 

R6,94,106,194 

23202-2200 

RES 2K00F W25 MF 50PPM 

R13,72,113,172  

23202-2240 

RES 2K40F W25 MF 50PPM 

R10,110 

23202-2300 

RES 3K00F W25 MF 50PPM 

R97,197 

23202-2360 

RES 3K60F W25 MF 50PPM 

R91,191 

23202-2390 

RES 3K90F W25 MF 50PPM 

R44,144 

23202-2430 

RES 4K30F W25 MF 50PPM 

R46,146 

23202-2470 

RES 4K70F W25 MF 50PPM  

R5,23,28,29,33,36,37,48,73,105,123,128, 
129,133,136,137,148,173 

23202-2560  

RES 5K60F W25 MF 50PPM 

R11,111 

23202-2680  

RES 6K80F W25 MF 50PPM 

R21,121 

23202-2750  

RES 7K50F W25 MF 50PPM 

R20,120 

23202-2820 

RES 8K20F W25 MF 50PPM 

R80,180 

23202-3100 

RES 10K0F W25 MF 50PPM 

R7,38,40,41,43,49,59,60,64,71,79,82,85, 
107,138,140,141,143,149,159,160,164, 
171,179,182,185  

23202-3120 

RES 12K0F W25 MF 50PPM  

R9,109  

23202-3180 

RES 18K0F W25 MF 50PPM  

R30,130 

23202-3200 

RES 20K0F W25 MF 50PPM  

R16,54,116,154  

23202-3220 

RES 22K0F W25 MF 50PPM  

R66,166 

23202-3270 

RES 27K0F W25 MF 50PPM  

R8,108 

23202-3300 

RES 30K0F W25 MF 50PPM  

R74,174  

23202-3330 

RES 33K0F W25 MF 50PPM 

R75,76,175,176  

23202-3360 

RES 36K0F W25 MF 50PPM  

R89,93,189,193  

23202-3430 

RES 43K0F W25 MF 50PPM  

R26,126 

23202-3470  

RES 47K0F W25 MF 50PPM  

R42,47,77,81,90,142,147,177,181,190 

23202-3560 

RES 56K0F W25 MF 50PPM 

R27,127 

 

  

 

15 

Содержание CPX200

Страница 1: ...CPX200 Dual 35V 10A Power Supply Service Manual Book Part Number 48511 0270 Issue 1...

Страница 2: ...Table of Contents Specifications 2 Safety 4 EMC 5 General 6 Circuit Descriptions 7 Calibration 12 Parts List 14 Component Layouts 22 Circuit Diagrams 25 1...

Страница 3: ...Typically 5m in constant voltage mode Typically 5k in constant current mode voltage limit at max Output Protection Forward protection by Over Voltage Protection OVP trip maximum voltage that should be...

Страница 4: ...ERAL AC Input 230V AC 14 50 60Hz Installation Category II Power Consumption 600VA max Operating Range 5 c TO 40 C 20 TO 80 RH Storage Range 40 C to 70 C Environmental Indoor use at altitudes up to 200...

Страница 5: ...ntional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may...

Страница 6: ...te that electrostatic discharge direct to the output terminals will not damage the instrument but may trip the Overvoltage Protection OVP turning the output off see Protection section Note also that i...

Страница 7: ...ning the top cover 2 To remove the upper control pcb proceed as follows Unplug the 26 way flat cables to the front panel pcb and the 16 way flat cables to the lower main pcb noting their orientation r...

Страница 8: ...rise an input filter which ensures that the supply meets both conducted emission and conducted immunity EMC requirements VDR1 clips mains spikes for component protection R3 provides safety discharge f...

Страница 9: ...e C23 at start up when VBULKA reaches about 150V there is enough voltage on C23 to turn on the high rail of IC1 and maintain the FET in an oscillating mode independent of output loading If for any rea...

Страница 10: ...the PWM controller IC5 This amplifier is configured as a voltage follower with a gain of one IC5 then converts this input signal into a pulse width modulated squarewave which is used to drive the two...

Страница 11: ...d into pin 4 of IC5 via the primary current limit circuit T2 D2 R2 VR5 R22 and R3 Measurement and Display The measurement system and display are controlled by a microcontroller IC11 The measurement of...

Страница 12: ...s VR1 and VR2 on the front panel board via PJ8 pin 3 and on to the ADC as VPROGA via adjustable attenuating chain R88 VR7 R89 for display of preset voltage level The OVP front panel preset potentiomet...

Страница 13: ...DMM set to 20A range in series with rheostat set to about 1 With output OFF set voltage controls to maximum and current control to 0 10A Switch output ON and adjust VR1 VR101 for 0 10A 01A on DMM Set...

Страница 14: ...approximately 17V note the exact reading Open the switch and adjust VR4 VR104 for exactly the same reading close the switch again and check the reading is unchanged Remove the diode resistor and swit...

Страница 15: ...OUND 3MM RED LED1 4 101 104 25061 9503 DISPLAY 4 DIGIT LED DISP1 2 101 102 27164 0506 IC ULN 2803A IC8 108 27231 2730 IC 74HC273 IC6 7 106 107 27234 5730 IC 74AC573 IC5 10 105 110 35555 2260 PCB FRONT...

Страница 16: ...MF 50PPM R44 144 23202 2430 RES 4K30F W25 MF 50PPM R46 146 23202 2470 RES 4K70F W25 MF 50PPM R5 23 28 29 33 36 37 48 73 105 123 128 129 133 136 137 148 173 23202 2560 RES 5K60F W25 MF 50PPM R11 111 23...

Страница 17: ...Cermet 10MM VR8 108 23379 3100 RES PS H10K Cermet 10MM VR2 3 102 103 23427 0331 CAP1N0K 63V CER HI K P5 C16 116 23427 0374 CAP 100PJ 100V CER N150 P2 5 C3 18 103 118 23427 0384 CAP 220PK 100V CER MED...

Страница 18: ...5 IC10 110 27160 0017 IC V REG 7812 IC8 108 27160 0440 IC V REG LM2940CT5 IC9 109 27161 0120 IC V REF ZN404 ZRA245 2 45V D23 123 27168 0020 IC UC3846N IC5 105 27226 0510 IC 4051B IC13 14 113 114 27250...

Страница 19: ...E L4 22300 0211 FUSEHOLDER PCB MOUNTING FOR FS1 22315 0248 FUSE 10A ANTISURGE T HBC CER FS1 22315 0402 FUSE 100mAT TL PCB MTG FS2 102 22520 0160 AC MAINS RECEP 10AMP R ANG MTG PJ3 22573 0202 HEADER 2...

Страница 20: ...7U 25V ELEC P2 C63 163 23557 0676 CAP 470U 63V ELEC P5 C15 16 115 116 23620 0246 CAP 100NK 63V P E P5 C19 21 24 26 27 62 119 121 124 126 127 162 23620 0261 CAP 100NK 400V P E C17 18 117 118 23620 9007...

Страница 21: ...0305 WASHER 5 16in SHK PRF I T ZPST GREEN TERMINAL 20038 9501 WASHER M3 Spring PCB FIXING 20038 9503 WASHER M3 5 SPRING TERMINALS 20234 0027 SCREW M3 X 6 PNHDPZ ZPST PCB FIXING 20657 0110 KNOB 15MM D...

Страница 22: ...E UPPER LOWER 20234 0027 SCREW M3 X 6 PNHDPZ ZPST PCB SPACERS 20234 0028 SCREW M4 X 10 PNHDPZ ZPST FEET 20662 0201 BRACKET PLAS FOOT 3786 7001 20662 0530 FOOT POLY E BLACK P2629 22491 0010 MAINS LEAD...

Страница 23: ...Component Layouts FRONT PANEL PCB 22...

Страница 24: ...CONTROL PCB 23...

Страница 25: ...MAIN PCB 24...

Страница 26: ...Circuit Diagrams 25...

Страница 27: ...CONTROL PCB PART CHANNEL A CHANNEL B IDENTICAL...

Страница 28: ...CONTROL PCB PART CHANNEL A CHANNEL B IDENTICAL...

Страница 29: ...MAIN POWER PCB...

Страница 30: ...Thurlby Thandar Instruments Ltd Glebe Road Huntingdon Cambridgeshire PE29 7DR England Telephone 44 01480 412451 Fax 44 01480 450409 e mail sales tti test com web site www tti test com...