OPERATING MANUAL

MAINTENANCE

WARNING

!

Do not attempt to repair or service the meter unless you are qualified 
to do so and have the appropriate calibration, performance test and 
service tools. If not, consult you Total Tools store for repair/service.

To avoid electrical shock or damage to the meter, do not get expose the meter to water or have 

it submerged in water.

GENERAL MAINTENANCE

 

Periodically wipe the case with a damp cloth and mild detergent.  

Do not use abrasives or solvents.

 

Turn off the power of the meter when it is not in use.

 

Take out the battery when the unit won’t be in use for extended periods.

 

Do not use or store the meter in an environment of high temperature, humidity, explosive, 

inflammable and strong magnetic field. The performance of the meter may deteriorate 

after dampened.

BATTERY/FUSE INSTALLATION AND REPLACEMENT  

Battery specification: 1.5V x4 AAA batteries

Fuse specification: mA input terminal: “F1” ,Φ5x20mm 630mA 250V 

20A input terminal: “F2” Φ5x20mm 20A 250V

!

Replace the battery immediately when the low battery indicator “ 

 “ appears on the LCD, 

otherwise the measurement accuracy might be  affected.
Make sure the test leads are disconnected from the circuit being tested before opening the 
case bottom.

1.  Switch the function dial to “OFF” position and remove the test leads;
2.  Remove the screw on the battery cover to replace the batteries and fuses
3.  Install ONLY replacement fuses with the identical type specified above and make sure the 

fuses are fixed firmly in the bracket. 

Note: blown fuses are not covered under warranty.

Содержание 151476 Series

Страница 1: ...ELECTRICIAN S MULTIMETER PART NO TTIDM1000V 151476 OPERATING INSTRUCTIONS...

Страница 2: ...tinuity Measurement 16 Capacitance Measurement 17 Frequency Duty Ratio Measurement 18 Temperature Measurement 19 Transistor Measurement 20 Non Contact Voltage Measurement NCV 21 Contact Type Live Neut...

Страница 3: ...thin the specifications the machine is rated for Failure to use the machine within the specifications may result in serious injury or death PRODUCT CONTENTS Unpack ensure the following attachments are...

Страница 4: ...eter that meet or exceed the safety requirements Comply with local and national safety codes Use personal protective equipment approved rubber gloves face protection and flame resistant clothes to pre...

Страница 5: ...and turn off the current to be tested before connecting the meter to the circuit After connecting the circuit reliably turn the current to be tested on Replace the battery as soon as the battery indi...

Страница 6: ...torage temperature 20 C 60 C 4 F 140 F Relative humidity 0 C below 30 C 75 30 C 40 C 50 Operating altitude 0 2000m Battery AAA 1 5V x 4 Low battery indication LCD displays symbol EMC a RF field 1V m o...

Страница 7: ...V DC voltage measurement V AC voltage measurement A AC current measurement A DC current measurement Live Contact type live neutral wire measurement OFF Shut down Hz Frequency duty radio measurement N...

Страница 8: ...battery indicator Diode measurement Continuity measurement Relative value measurement k M Resistance unit mV V Voltage unit A mA A Current unit nF F mF Capacitance unit Hz Frequency unit duty radio C...

Страница 9: ...to cycle through the sensing range of EFHI and EFLo In the off state press and hold the SEL REL key then rotate the function dial to turn on the device The product enters the non sleep mode and the b...

Страница 10: ...Restart the meter to restore the Auto off function BUZZER WARNING Input AC DC voltage 1000V buzzer warning and red indicator is on high voltage symbol appears indicating that the range is at its limi...

Страница 11: ...most cases if the circuit impedance is under 10k the error can be ignored 0 1 The input impedance of DC mV scale is infinite 1000M and it does not attenuate when measuring weak signals so the measure...

Страница 12: ...ing to the current being measured connect the common test lead to COM terminal then insert the red test lead to mA A or 20A terminal 2 Connect the test leads with the circuit in series NOTE Readings o...

Страница 13: ...ce is greater than 0 5 when the test leads are shorted please check if the test leads are loose or damaged When measuring high resistance at 60M range it takes a few seconds to stabilise the readings...

Страница 14: ...to activate the diode measurement 3 Connect the common test lead to COM terminal then insert red test lead to Hz V C terminal 4 Connect the red probe to diode anode black to diode cathode 5 Reading 0...

Страница 15: ...L OFF A HOLD NPN PNP E c b e B C TTIDM1000V True RMS OFF Live NCV 600m 6 60 60 60m 60m C F Hz hFE 600 6k 60k 600k 100mF 6M 60M 60 6 600 600 600m 600m 20 20 1000 1000 V A V A Hz Hz C mA A 20A MAX FUSED...

Страница 16: ...t lead to Hz V C terminal 3 Connect the probes to the circuit test points 4 Measured resistance 30 The circuit is broken buzzer makes no sound red indicator is on Measured resistance 30 The circuit is...

Страница 17: ...If the measured capacitor is short circuited or the capacitance exceeds the maximum range the OL symbol will appear on the screen When measuring large volume capacitors it may take a few seconds to ob...

Страница 18: ...cy value is displayed on the screen 4 Short press 2s SEL REL button to perform duty ratio measurement 5 When measuring AC voltage or AC current you can short press 2s the SEL REL button to switch to f...

Страница 19: ...button to switch between C F NOTE OL symbol appears when the meter is turned on F 1 8x C 32 True RMS OFF Live NCV 600m 6 60 60 60m 60m C F Hz hFE 600 6k 60k 600k 100mF 6M 60M 60 6 600 600 600m 600m 20...

Страница 20: ...The reading on the screen is the amplification factor of the measuring transistor Amplification factor 50 green indicator is on indicates the amplification is good Amplification factor 50 yellow indi...

Страница 21: ...f sensing level 1 the green indicator will start flashing and the buzzer will beep intermittently According to the intensity of the induced voltage the green indicator flashes with varied frequencies...

Страница 22: ...flash and the buzzer will beep According to the voltage value of the live wire the indicator flashes with varied frequencies and the buzzer beeps with different intermittent time The measured voltage...

Страница 23: ...ce the load is connected 5 digits Max input voltage 1000V Input voltage 1000V audio visual alarm Input voltage 1010V OL appears on LCD AC VOLTAGE MEASUREMENT RANGE RESOLUTION ACCURACY RANGE RESOLUTION...

Страница 24: ...5 6k 0 001k 0 8 3 60k 0 01k 600k 0 1k 6M 0 001M 1 5 5 60M 0 01M 1 5 25 Measurement result reading of resistance reading of shorted test leads Open circuit voltage about 1V test current is about 0 4mA...

Страница 25: ...mF 100 F 10 0D Overload protection 600V PTC Measured capacitance 600nF It is recommended to select REL mode for ensuring accuracy open circuit allows least significant digit 20 DC CURRENT MEASUREMENT...

Страница 26: ...hen crest factor is 2 5 3 AC current frequency measurement 45Hz 1KHz Min measurement range mA gear position 35mA 20A gear position 5 5A Accuracy guarantee range 1 100 of range open circuit allows leas...

Страница 27: ...green LED flickers from slow to fast buzzer beeps from slow to fast LED on yellow 48V 220V yellow LED flickers from slow to fast buzzer beeps from slow to fast LED on red 220V red LED is on LIVE LED...

Страница 28: ...ication factor 50 LED off Amplification factor 0 Capacitance LED off 20pF LED on green The capacitor is fully charged LED on yellow The capacitor is charging Voltage LED off DCV 1000V ACV 1000V LED on...

Страница 29: ...perature humidity explosive inflammable and strong magnetic field The performance of the meter may deteriorate after dampened BATTERY FUSE INSTALLATION AND REPLACEMENT Battery specification 1 5V x4 AA...

Страница 30: ...30 ELECTRICIAN S MULTIMETER...

Страница 31: ...31 OPERATING MANUAL...

Страница 32: ...be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also ent...

Отзывы: