enter into the mist device. Adjust the flowrate to make liquid flow out of the nozzle
in droplet status, then press button B again to close the pump.
(3) Rotate the valve B counterclockwise and observe the pressure meter, stop
rotating when the value reaches at 0.3~0.4Mpa.
(4) Press button A, then there will be sound of gas entering the mist device.
Release button A.
(5) Rotate the valve B counterclockwise for more 5
°
quickly.Press Button A
once again and wait for approximate 2 seconds. Some current sound of spark
plug will be heard, then the gas in the mist device will be ignited and burn stably
(6) 5 seconds after the gas burning stably, press button B to open the pump to
let the drug liquid enter into the mist device.
(7) The fog will increase with the rising of temperature of mist device to final
stable status.
(8) The mist device should be fully cooled down before power off.
①
Firstly
close the valve B to cut off the gas supply.
②
Secondly do not close the pump
until there is not any fog exist,
③
Keep the fan working for additional 5
minutes ,then shut down the power of mist device.