5.2.5.3 Voltage Calibration Settings
Flight controller voltage sensor need to be calibrated if flight controller voltage sensor
result is different from real voltage.Real battery voltage should be filled in measured
voltage,flight controller voltage will be calibrated by clicking save.
It’s unnecessary to set
by user as calibration has been done before delivery.
5.2.5.4 Low Liquid Protection
When liquid is nearly out, the following reaction could be set: Off(Close the protection),
Return(auto home landing), Hovering, Hovering & landing. The default is Off, which
means only LED flash as alarm.
We suggest you to set it on Return option.
5.2.5.5 Spraying Mode
The drone has 2 spraying modes : Combination & Manual mode.
Combination mode: Spraying rate will follow flying speed. Faster speed, bigger flow rate.
Manual mode: Spraying always work under the biggest flow rate when in this mode.
Combination control of the pump,max flow rate match to max flying speed. The maximum
default combination number is 6m/s,minimum default combination number is 0.2m/s.