6
471C
Installation
Installation conditions
Power supply
AC100
to
240V 50/60Hz
,
DC24V
Voltage tolerance of
power supply
AC90
to
250V
,
DC24V
±
10%
Power consumption
During AC100V: Approx. 9VA
,
During AC200V: Approx. 12VA
During 24VA: Approx. 200mA
Operating ambient
temperature
0
to
50
℃
, 40
to
85%RH
(
No condensation
)
Storage temperature
-
20
to
65
℃(
No condensation
)
Weight
Approx. 300g
Mounting method
Tighten from behind the panel with exclusive mounting bracket.
Insulation resistance
Measuring input terminals
–
External Case DC 500 V, More than 100 M
Ω
Power supply terminal
–
External Case DC 500 V, More than 100 M
Ω
Power supply terminal
–
Measuring input DC 500 V, More than 100 M
Ω
Measuring input terminals
–
BCD output DC 500 V, More than 50 M
Ω
Measuring input terminals
–
Analog output DC 500 V, More than 50 M
Ω
Withstand
voltage
Measuring input terminals
–
External Case AC 2000 V for one minute
Power supply terminal
–
External Case
AC 2000 V for one minute
Power supply terminal
–
Measuring input
AC1500 V for one minute
Measuring input terminals
–
BCD output, RS-232C, RS-485 AC 500 V for one minute
Measuring input terminals
–
Analog output AC 500 V for one minute
Protective structure
Front operation unit IP65, Case part except front side
IP20,
Terminal block
IP00
Accessories
Make sure that the following
items
are included with
product supplied.
・
471C main unit
・
Bracket 2pcs.
・
Waterproof packing
・
Quick Manual (This booklet)
(For the model with RS-232C or RS-485, exclusive quick manual is included.)
・
Unit Sticker
・
Connector (2m with flat cable) (In case of BCD Output model)