TSOL-MP3000/MP2250/MS3000
V1.4
- 7 -
Datasheet
Model
MP2250
MP3000
MS3000
Input Data (DC)
Quantity of Input
4 Connectors
4 Panels
6 Connectors
5 - 6 Panels
4 Connectors
7 - 8 Panels
Recommended Module Power (W)
480 ~ 700+
480 ~ 700+
440 ~ 600+
Start-up Voltage per Input (V)
22
22
36
Rated Input Voltage (V)
42
42
84
MPPT Voltage Range per Input (V)
18~60
18~60
32~120
Max. Input Voltage per Input (V)
60
60
120
Max. Short-circuit Current per Input
(A)
20
20
16
Max. Input Current per Input (A)
18.5
18.5
15
Quantity of MPPT
4
6
4
Max. Inverter Back-feed Current to
the Array (A)
0
0
0
Output Data (AC)
Max. Output Power (VA)
2250
3000
3000
Nominal Continuous Output Power
(W)
2250
3000
3000
Nominal Output Current (A)
10.1
13.6
13.6
Max. Output Current (A)
11
14
14
Inrush Current (A)
20
25
25
Max. Output Fault Current (A)
45
50
50
Max. Output Overcurrent Protection
(A)
27
27
27
Nominal Output Voltage/Range (V)*
220/230/240, 175 – 270, L/N/PE
Nominal Frequency (Hz)*
50/60
Power Factor
>0.99 default
,
0.8 leading … 0.8 lagging
Output Current Harmonic Distortion
<3%
Efficiency
Peak Inverter Efficiency
97.0%
97.1%
97.2%
CEC Weighted Efficiency
96.5%
96.6%
96.7%
Nominal Mppt Efficiency
99.9%
99.9%
99.9%
Nighttime Power Consumption
<1W
<1W
<1W
Protection
Anti-Islanding protection
Integrated
DC reverse polarity protection
Integrated
Insulation monitoring
Integrated
AC surge protection
TYPE II
Residual current monitoring
Integrated
AC overcurrent protection
Integrated
AC short-circuit protection
Integrated
AC overvoltage protection
Integrated