Tsubaki TSM4000H2 Скачать руководство пользователя страница 25

- 24 - 

 
■Sensor cable

                                                 

■I/O cable 

TSM4-S01, TSM4-S03, TSM4-S05

                       

TSM4-C01 

TSM4-S10, TSM4-S20, TSM4-S30

                       

TSM4-C03 

 
 
 
 
 
 

18. Warranty

18. Warranty

18. Warranty

18. Warranty    

18.1 Free warranty period 

TC shall offer free warranty period of 18 months after the shipment from the factory or 
12 months after the beginning of the use (counted from the completion of the installation 
of the TC product into your equipment), whichever is shorter. 

 

18.2 Warranty coverage 

Any failure or malfunction occurred in the TC product within the free warranty period 
shall be repaired or be handled by replacing the failed part with no charge through the 
return of the product to TC, as long as the proper installation, usage, and maintenance in 
accordance with the instruction manual are provided by the customer. 
Note, however, that this free warranty shall cover only the TC product delivered to the 
customer and the following expenses shall not be covered by the warranty. 

(1)

 

The cost for the removal or installation of the TC product from or to the customer's 
equipment for the purpose of replacement or repair, and the cost associated with such work. 

(2)

 

The transportation cost for sending the customer's equipment to the customer's 
repair plant or other place. 

(3)

 

The lost earnings of the customer resulted from the failure and/or repair, as well as 
other increased damages. 

 

18.3 Paid warranty 

Even within the free warranty period, if a failure or malfunction occurs in the TC product 
due to any of the following causes, the investigation/repair shall be charged. 

(1)

 

The customer did not install the TC product properly in accordance with the 
instruction manual. 

(2)

 

The customer did not handle the product properly and/or did not provide sufficient 
maintenance. 

(3)

 

The failure or malfunction was resulted from improper connection between the TC 
product and other equipment. 

(4)

 

The customer changed the structure of the TC product such as modification. 

(5)

 

The TC product was not repaired at TC or TC-designated plants. 

(6)

 

The TC product was not used in the appropriate operating environment described in 
the instruction manual. 

(7)

 

The failure or malfunction was caused by force majeure such as disasters or by 
illegal behavior of a third party. 

(8)

 

The failure of the TC product was caused incidentally by the malfunction of the 
customer's equipment. 

(9)

 

The failure was caused by the installed customer-supplied part or by the part used 
in accordance with the designation of the customer. 

(10)

 

The failure was caused by failed wiring or incorrect parameter setting conducted by 
the customer. 

(11)

 

The product has reached its life which is normal for the operating condition. 

(12)

 

Damage occurred due to the cause for which TC was not liable. 

 

 

 

 

C

o

n

te

n

ts

 

U

s

a

g

e

 

/N

a

m

e

s

 

S

a

fe

ty

 

In

st

al

la

tio

n

 

/W

ir

in

T

er

m

in

a

ls

 

C

on

n

ec

tio

n

 

O

p

e

r

a

ti

o

n

 

M

ai

n

te

n

an

ce

/In

sp

ec

tio

n

 

Sp

ec

ifi

ca

tio

ns

 

D

im

en

si

on

s

D

im

en

si

on

s

D

im

en

si

on

s

D

im

en

si

on

s    

W
a

rr

a

n

ty

W
a

rr

a

n

ty

W
a

rr

a

n

ty

W
a

rr

a

n

ty

    

Содержание TSM4000H2

Страница 1: ...nd users who will actually use this product Keep this instruction manual safe from loss until this product is discarded This product is subject to change without prior notice Instruction Manual Publis...

Страница 2: ...medium to light injury or property damage can occur Even if the instructions are followed a serious consequence may result depending on the situation Be sure to exercise due caution and follow all of...

Страница 3: ...heck functions and operation periodically according to the instruction manual If any malfunction is found contact your dealer for repair Do not use the Shock Monitor in an atmosphere where any corrosi...

Страница 4: ...ic power values can be output as analog voltage signals Output relay switching The output relay can be switched between Self Hold and Auto Reset Power detection response setting When the load pulsates...

Страница 5: ...included as an accessory If this cable length is insufficient optional cables of 3 m 5 m 10 m 20 m and 30 m are available Contact TC when necessary 5 Part Names 5 Part Names 5 Part Names 5 Part Names...

Страница 6: ...ult 7 Wiring 7 Wiring 7 Wiring 7 Wiring Complete wiring by using only the socket before attaching the Shock Monitor main unit to the socket Connect a commercial power supply of 90 to 250 VAC 50 60Hz o...

Страница 7: ...through sensor Motor rated current A Sensor model No No of times to pass wire through sensor 0 1 0 71 TSM U010 6 0 36 TSM U010 12 0 2 1 4 TSM U010 3 0 70 TSM U010 6 0 4 2 3 TSM U010 2 1 2 TSM U010 3 0...

Страница 8: ...way from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit and their outpu...

Страница 9: ...minute current 10 mA or less is connected activate a relay for minute current with a relay output and then connect the contact of the relay for minute current to a sequencer photocoupler input 8 2 Co...

Страница 10: ...sage Names Safety Installation Wiring Terminals Terminals Terminals Terminals Connection Operation Maintenance Inspection Specifications Dimensions Warranty 1 mA max 100 200 5 10 V 0 Load ratio Analog...

Страница 11: ...class resistor TSM4 PR1 Contents Usage Names Safety Installation Wiring Terminals Connection Connection Connection Connection Operation Maintenance Inspection Specifications Dimensions Warranty This d...

Страница 12: ...perational power supply Do not connect the secondary side of the inverter Contents Usage Names Safety Installation Wiring Terminals Connection Connection Connection Connection Operation Maintenance In...

Страница 13: ...put relay Return to parameter 1 Show the Test Program mode switching screen Change to the Monitor mode Change to the Monitor mode Change the monitor screen Conduct the operation test of the relays Rel...

Страница 14: ...ting values for High1 and High2 For power monitoring the displayed load ratio is a value calculated on the assumption that the selected motor capacity is 100 Turning on the operational power supply TS...

Страница 15: ...applied PROGRAM MODE SET Contents Usage Names Safety Installation Wiring Terminals Connection Operation Operation Operation Operation Maintenance Inspection Specifications Dimensions Warranty The Hig...

Страница 16: ...tor disables the relay output function for a specified period after it is started even in the Monitor mode Counting starts when the detected electric power reaches 5 or the current reaches 10 of the r...

Страница 17: ...condition is cleared High2 5 to 200 Set the High2 output level Output is activated when the load ratio reaches or exceeds this setting value for the period specified at 8 Shock Time or longer 5 5 5 5...

Страница 18: ...requency continues changing at the rate of 4 Hz or higher per second inhibit function is activated regardless of the inhibit time setting 2 Off The Auto Inhibit is disabled Reference value writing met...

Страница 19: ...write the reference load ratio manually by pressing the and keys simultaneously while the motor is running Timing chart 1 4 1 4 1 4 1 4 L C D B a c k l i g h t L C D B a c k l i g h t L C D B a c k l...

Страница 20: ...ay High1 indicator MIN 0 1s When parameter 6 is set to Auto Reset 12 Offset Mode 2 X1 Start Time Shock Time High1 Operating level tracking Reference value ON Shock Time RUN indicator High1 indicator H...

Страница 21: ...o the actual load Model number of the current sensor Wrong Replace with a correct sensor Does the V phase motor wire pass through the current sensor Other phase U phase or W phase Install the wiring p...

Страница 22: ...voltage test remove the Shock Monitor main unit from the socket to avoid test voltage 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 1 Inspect that the MO...

Страница 23: ...Contact capacity 1c contact 250 VAC 0 5A Inductive load cos 0 4 30 VDC 0 4 A Inductive load 110 VDC 0 2A Inductive load Minimum load 24 VDC 4 mA Life 100 000 times of operation Analog output signal 0...

Страница 24: ...0H2P TSM4 PR1 TSM4 PL1 37 46 4 45 54 5 63 5 20 8 C u r r e n t d i r e c t i o n m a r k Mounting hole 2 4 20 5 Mounting hole 4 6 C u r r e n t d i r e c t i o n m a r k Mounting hole R2 3 24 1 4 40 7...

Страница 25: ...id warranty Even within the free warranty period if a failure or malfunction occurs in the TC product due to any of the following causes the investigation repair shall be charged 1 The customer did no...

Страница 26: ...MEMO MEMO MEMO MEMO...

Страница 27: ...MEMO MEMO MEMO MEMO...

Страница 28: ...Ltd http tsubaki sg U S Tsubaki Power Transmission LLC http www ustsubaki com Taiwan Tsubakimoto Co http tsubakimoto com tw Tsubaki of Canada Limited http tsubaki ca Tsubakimoto Chain Shanghai Co Ltd...

Отзывы: