background image

 

䠉㻌

3

㻌 䠉

 

3

Checking the package 

Upon receiving the Shock Relay, please check the following: 

Check whether the model and specification conform to what you ordered. 

Check to see no damages occurred during the delivery.  

Package: Shock Relay, Instruction Manual 

 

Model Identification

 

 

ᵲᵱᵠᴾᵎᵐᵎᴾᵣᵢ

 
 
 
 
 
 
 
 
 
 
 

4. Demensions

 

 

 

Maximum Motor Capacity (class 200V ) 
020   0.2kW 
075   0.75kW 
220

 

   

 

2.2kW 

550   5.5kW

 

ED series 

SHOCK RELAY 

 

Cover 

Mounting hole 

Screw 

 

Содержание TSB020ED

Страница 1: ...hly before installing wiring operating and inspecting this SHOCK RELAY Please make sure that this instruction manual accompanies the SHOCK RELAY to the end user Please keep this instruction manual saf...

Страница 2: ...his instruction manual the rank of safety requirements is divided into WARNING and CAUTION Death or serious injury may result from product misuse due to not following the instructions Minor or moderat...

Страница 3: ...operation Electric Shock Risk The wiring operation maintenance check of Shock Relay must be performed by workers with expertise Electric Shock Injury Fire Risk CAUTION In case the instruction manual i...

Страница 4: ...model and specification conform to what you ordered Check to see no damages occurred during the delivery Package Shock Relay Instruction Manual Model Identification 4 Demensions Maximum Motor Capacit...

Страница 5: ...4 5 Specifications...

Страница 6: ...ent CAUTION Keep Shock Relay free from lint paper wooden chips dirt dust metal scrap etc Fire Accident Risk CAUTION Avoid usage in the corrosive gas environment Sulfide gases SO2 H2S corrode cooper an...

Страница 7: ...3 Never contact the output of an inverter or a servo driver to terminal A1 A2 4 Install an insulation transformer between the power line and terminal A1 A2 of the Shock Relay when harmonic noise is i...

Страница 8: ...ass the main winding line 4 If the capacity of the operating electromagnetic coil of the electromagnetic contactor is above 200VA during closing time or 20VA during holding time then drive a secondary...

Страница 9: ...reen when a preset VR is turned Trip relay will be energized when current exceeds Current Level and goes on beyond Shock Time Dip Switch TEST Button When LED indication is a current value if TEST Butt...

Страница 10: ...y movement Locked Motor Trip Current value and set current are displayed when A is indicated Start time and shock time set up are displayed when s is indicated LVSOD 95 96 95 96 A M A M 97 9 1s 97 98...

Страница 11: ...Shock time monitor screen indicates o Over load trip After over load trip monitor screen indicates o Monitor screen keeps Actual current at over load trip in case that Dip switch is set to M Manual re...

Страница 12: ...e machine It kept being charged with electricity beyond 200 of the CURRENT setup value after the start during the sum of the start time and 0 2 sec Check whether there is a wrong point in the machine...

Страница 13: ...ed properly Check a power source voltage A1 A2 by voltage tester It is different from proper supply voltage TSBED 24 240V Aproper power supply is input Relay does not trip even if current setting valu...

Страница 14: ...the 2 1 1 General Standard of Ordinance on Labor Safety and Hygiene 16 Daily check LED lights when Shock Relay is power on 17 Periodic check Check whether there is any looseness in the installation o...

Страница 15: ...Costs to reimburse any profit loss due to any repair or damage and consequential losses caused by the Buyer 18 3 Warranty with charge Seller will charge for any investigation and repair of Goods caus...

Страница 16: ...aki Power Transmission LLC http www ustsubaki com Taiwan Tsubakimoto Co http tsubakimoto com tw Tsubaki of Canada Limited http tsubaki ca Tsubakimoto Chain Shanghai Co Ltd http tsubaki cn Tsubaki Aust...

Отзывы: