6
8. Overload Detection
⚫
The axial movement of the sensor plate is used to determine overload.
⚫
The plate moves with every trip revolution. Use a proximity switch that can sufficiently detect the sensor plate displacements as
shown in the table below.
⚫
If using a TGA sensor, read and follow the instructions provided in its manual.
Unit : mm
Model No.
t
Displacement of
Sensor Plate
TGB20-H
1.8 --- 3.3
1.8
TGB30-L,H
2.0 --- 3.5
2.0
TGB50-L,M,H
2.7 ---4.2
2.7
Unit : mm
Model No.
t
Displacement of
Sensor Plate
TGB70-H
3.3 --- 4.8
3.3
TGB90-L,H
5.6 --- 6.8
5.4
TGB110-L,H
6.2 --- 7.4
6.0
TGB130-L,H
6.8 --- 8.0
6.6
9. Resetting
This auto-resetting type only requires restarting the motor, and other parts of the drive unit to reengage.
①
When the TGB trips from overload, stop the motor and remove the cause of overload.
②
Reset TGB and operate at 50 rpm or slower or by inching the motor. Never reset manually.
③
The clicking noises indicate that the drive balls have rolled back into their positions.
10. Maintenance
①
SHOCK GUARD
Apply a thin layer of grease to the drive balls and Thrust bearing, once a year or every 1000 trips.
Grease
Mobil
Showa Shell
Eneos
Idemitsu
Cosmo
Mobilux
EP2
Alvania
EP Grease 2
Epnoc Grease
AP(N)2
Daphny Eponex
Grease EP No.2
Cosmo Dynamax
EP Grease 2