4.  Specifications 

Series

 

TSB SA

 

Type 

Range

 

05 

0.5 - 5A 

10 

1 – 10A 

30 

3 – 30A 

Current Setting 

*

1

 

60 

5 – 60A 

Starting Trip Delay  Start Time 

0.2 - 10s 

Time Setting 

*

1

 

Trip Time 

Shock Time  0.2 - 5s 

Accuracy 

Current 

±10

 (full scale) 

Control Power Supply 

100

240VAC, 50/60Hz 

*

2

 

Rated Voltage 

600VAC, 50/60Hz 

Current Sensing 

2 Integral Current Transformer 

Mode 

1-SPDT(1-C) 

Rating 

3A / 250VAC, Resistive 

Minimum applicable load 

*

3

 

DC10V, 10mA 

Output Relay 

Status 

Normally De-Energized 

Mechanical 

10,000,000 Operations 

Expected Output 
Relay Life 

Electrical 

100,000 Operations 

Display 

Monitor(MON,green), Over Current(OC,red) 

Reset 

Auto Reset after 1s 

Operating 

-20 - +60

 (-4 - +158 F) 

Temperature 

Storage 

-30 - +70

 (-22 - +176 F) 

Ambient Environment 

Humidity 

45 - 85

 RH without Condensation 

Insulation 

Between casing and circuit 

Over 10M

Ω

with 500 VDC Megger 

Between casing and circuit 

AC 2000V, 5mA, 60Hz, 1min 

Between contacts 

AC 1000V, 5mA, 60Hz, 1min 

Dielectric Strength 

Between circuits 

AC 2000V, 5mA, 60Hz, 1min 

115VAC 

2.70 VA(0.35W) 

Power Consumption 

230VAC 

11.00 VA(1.2W) 

Case 

Upper:PA6, Bottom:PA66 

Material 

Terminal cover 

PA6 

Mounting 

35mm DIN rail or Panel 

Dimension(WxHxD /Including Integral CT Windows) 

54x60x65mm 

Weight 

Less than 200g (0.445LBS) without External CT 

 

*1  Current and time setting ranges can be set within the warranty range, but not the upper or lower 

level of setting volume.

 

*2  When Shock Relay Is used with Inverter, the output frequency of Inverter should be from 30Hz  
     to 60Hz. 

*3

 

When directly inputting output relay contact into the programmable controller (PLC), be aware 

that a minute electric current can cause contact failure

.

 

As for the input to PLC, it is commended 

to drive the relay coil for minute current by relay signal of Shock Relay at first, then input this 
relay contact to PLC. 

 

Содержание SHOCK RELAY TSB2CT Series

Страница 1: ...Edition When revisions of these standards are published the updated edition shall apply 6 Guards must be provided on all power transmission and conveyor applications in accordance with provisions of...

Страница 2: ...ation to adjustment Be sure to read this manual carefully before using your Shock Relay When delivering a device containing the Shock Relay be sure that this instruction manual is included 2 TSBSA and...

Страница 3: ...2 3 Dimensions Shock relay Attachment Cover Screw Unit mm 1inch 25 4 mm...

Страница 4: ...3 External 2 phase CT Details for installation holes...

Страница 5: ...Over 10M with 500 VDC Megger Between casing and circuit AC 2000V 5mA 60Hz 1min Between contacts AC 1000V 5mA 60Hz 1min Dielectric Strength Between circuits AC 2000V 5mA 60Hz 1min 115VAC 2 70 VA 0 35W...

Страница 6: ...n of the arrow to remove the mounting bracket 2 Install the Shock Relay to the DIN rail 6 Wiring 1 Connect 90 250VAC power source to the terminal A1 A2 Never connect the output of an inverter or a ser...

Страница 7: ...1 2 2 3 TSBSA10 1 2 2 3 TSBSA05 1 3 7 5 TSBSA30 3 7 5 TSBSA10 1 5 5 7 1 2 TSBSA30 1 5 5 7 1 2 TSBSA30 1 7 5 10 TSBSA60 1 7 5 10 TSBSA30 11 15 TSBSA60 1 11 15 TSBSA30 1 15 20 TSBSA60 1 18 5 25 TSBSA60...

Страница 8: ...urrent 100A 200A 300A Ratedsecondarycurrent 5A Ratedburden 5VA Ratedfrequency 50 60Hz Approximatelyweight 0 5kg Installation Procedure 1 Install the SHOCK RELAY on the External CT with screws accordin...

Страница 9: ...y has elapsed Shock Relay will return to normal condition MON lamp green shows monitor condition It is turned on under the normal monitor condition and the relay turns off the lights while it is outpu...

Страница 10: ...he running current is commonly used 6 Reset the START TIME knob to match the normal run up time 7 Periodic testing by using the TEST button is suggested to ensure the full protection through preventiv...

Страница 11: ...product begins to operate improperly be sure to take measures to prevent a dangerous situation from arising 16 Guarantee Range of guarantee With regard to any troubles happened to our products replac...

Страница 12: ......

Отзывы: