7
6. Trouble shooting
Most of jack troubles arise from improper lubrication, inappropriate selection, and misalignment. Please use the
following trouble shooting table when investigating problems.
Table 6. Trouble shooting
Trouble
Cause
Action
Gear Housing
Failure
1. Over load
2. Improper support
3. Shock
・
Reduce the load or replace with a unit of sufficient capacity.
・
Install the jack to a robust base and align proplerly.
・
Provide a shock absorbing device.
Input
Shaft
Failure
1. Improper centering
2. Excessive overhung load
3. Overload
4. Impact load
5. Excessive input
・
Tube coupling may cause shaft failure. Please use flexible
coupling.
・
Re-align as mentioned in installation page.
・
Check the catalog for allowable loads and adjust.
・
See Gear Housing Failure #1.
・
Provide a safety device to avoid possible impact loads.
・
Set the input power to be less than the allowable input torque
in the catalog or replace it with a larger unit.
・
When several jacks are connected in series, there is a
limitation on the input shaft of the first jack due to the axia
strength. If the current value exceeds the catalog value, reduce
the load or change the jack to one with a larger capacity
Bearing
Failure
1. Overload
2. Excessive overhung load
3. Coupling misalignment
4. Coupling axial adjustment
5. Abnormal force to
worm wheel bearings
6. Improper lubrication
7. Impact load
・
See Gear Case Housing #1.
・
See Input Shaft Failure #2.
・
See Input Shaft Failure #1.
・
Although the specified pressure has been applied to the
bearing, the input shaft can be rotated freely when no load is
connected. If the rotation is heavy, some force may be
applied to the input shaft in the axial direction. Remove the
force.
・
See #5 (Maintenance and inspection) of this manual.
・
See Input Shaft Failure #4.
Abnormal wear of
travel nut/
worm wheel
1. overload
2. Improper lubrication
3. Improper
adjustment/installation
・
See Gear Housing Failure #1.
・
See Bearing Failure #6.
・
Set the load so that it will be applied onto the same axis as the
screw shaft.
Ball nut damage,
abnormal wear
1. Overload
2. Improper
adjustment/installation
3. Improper lubrication
4. Inappropriate sizing
・
See Gear Housing Failure #1.
・
Set the load so that it will be applied onto the same axis as the
screw shaft.
・
See Bearing Failure #6.
・
Check the catalog for relationship between life and load.
Shaft failure,
Abnormal abration,
abnormal noise
1. Overload
2. Improper
adjustment/installation
3. Side load
4. Improper lubrication
・
See Gear Housing Failure #1.
・
See Ball Nut Failure #2.
・
Provide a guide to avoid side loads
・
See Bearing Failure #6.
Gear Housing
overheat
(over 80
℃
)
1. Overload
2. Improper lubrication
3. Improper centering
・
See Gear Housing Failure #1.
・
See Bearing Failure #6.
・
See Input Shaft Failure #1.
・
See Shaft Failure #3.
Содержание LINIPOWER
Страница 20: ...17 Output wave form Signal 1 Signal 2 Signal 3 Forward Output circuit ...
Страница 22: ...19 ...