Open the locking part from the end of the openable
tube.
Install the cable or tube inside the openable tube.
Cable/tube installation procedure and locking part opening and closing procedure
Handling Instructions
1
2
Procedure for installation on equipment
1
2
After inserting the cable/tube and before mounting it
on the equipment, the locking part of the openable
tube should be facing outward, and the Flatveyor
should be bent as shown in the figure above.
Fix the fixed end and the moving end to the
equipment using clamps in the state shown in 1.
Make sure that section A is correctly overlapped
around the entire length of the Flatveyor as shown in
the figure above.
Temporarily tighten the end of the openable tube by
hand.
3
4
Close the locking part from the end of the openable
tube using the closing tool. (Also closable by hand)
5
Section A
Ensure that the locking part of the openable tube is
properly closed.
Check that the bending section of the Flatveyor is not
tilted and that the unsupported length is not twisted.
3
4
Open
Inclination of
bending section
Twisting of
unsupported
length
Closed
Fix each cable/tube at both the fixed end and the
moving end using a cable tie or similar implements.
Move the Flatveyor slowly to ensure that each
cable/tube is not pulled into the openable tube.
Check that there are no other operation abnormalities.
5
6
Check that the locking part is properly closed.
Refer to figure 7 on page 16.
6
Uniform gap at the
locking part over
the entire length