background image

Check of installation dimensions

Step 4

Page

6

Item

Installation dimensions

Reference information

Check the space required for installation.

If the operating conditions exceed the load diagram, contact a Tsubaki representative.

Mounting height

223 to 243 mm

Required space (Width)

186 mm

Required space (Height)

323 to 343 mm

Example:

186 mm

223 to 243 mm

323 to 343 mm

Page

5

Item

Basic specifications

6

Fixing parts and installation dimensions

Reference information

Calculation of the number of support member links

Step 5

2

S

2

(

H’

 − 23) × 

π

+ 2

K

 + 2

CL

 + 

P

Number of support member links =

Fixed end

Moving end

Travel length 

S

Clamp length 

CL

Leeway length 

K

Mounting height 

H’

Support member

bending radius 

R

R = 70/100/130

S
H’
K
P
CL

: Travel length (mm)
: Mounting height (mm)
: Leeway length = 100 or more (mm)
: Support member pitch (mm)
: Clamp length = 50 mm 
  (Recommended)
: Fixed number for calculation

Determination of color

Step 6

Determine the color of the product.

Number of links

49 links

+

2

600

2

(233 − 23) × 

π

+

+ (2 × 100) + (2 × 50) + 46

20

Number of support member links =

In case of 

S

 = 600, 

H’

 = 233, support member bending radius R070

= 48.7933...
= 49

Example:

The formula is for the case when the 

fixed end is at the center of the travel 

length. After calculating, always round 

up to a whole number.

Note:

Black

White

9

10

Operating conditions:

Travel length: 

0.6 m

Cable mass per meter:  0.195 kg/m

Unsupported length (m)

S

 

Travel length (m)

0.1

2

1

0.1

0

0.5

1

1.51.6

0.9

0.87

(kg/m)

Check of capability with a load diagram

Step 3

Page

11 to 12

Item

Load Diagram

Reference information

Using the load diagram that shows the required number of openable tubes 
and the support member bending radius, check that the operating conditions 
(travel length, cable/tube mass) are within the capability range.

Example:

No.

(1)
(2)
(3)

Cable outer

diameter

mm

6.6
7.1
7.2

With/without

shield

Shielded
Shielded
Shielded

Quantity

1
1
1

0.052
0.070
0.073

Mass

kg/m

Installation cables

Support member bending radius

R070

Cable allowable bending radius = 7.2 × 8

                                                    = 57.6 mm
Select a support member

bending radius greater

than 57.6 mm.

No.

(1)
(2)
(3)

Cable outer

diameter

mm

6.6
7.1
7.2

With/without

shield

Shielded
Shielded
Shielded

Quantity

1
1
1

0.052
0.070
0.073

Mass

kg/m

Example:

Installation cables

Selection

Determination of required number of openable tubes and required space (width) dimensions

Step 1

Page

Item

Reference information

Determine the cable/tube arrangement and 
required number of openable tubes. After they have 
been determined, check the required space (width).

Required number of openable tubes

3

Required space (Width)

186 mm

Example:

5
6

Number of cables (jackets) and tubes to be installed and recommended materials
Installation dimensions

(3)

(2)

(1)

No.

(1)
(2)
(3)

Cable outer

diameter

mm

6.6
7.1
7.2

With/without

shield

Shielded
Shielded
Shielded

Quantity

1
1
1

0.052
0.070
0.073

Mass

kg/m

Installation cables

Determination of support member bending radius

Step 2

Page

5

Item

Basic specifications

Reference information

Determine the support member bending radius based on the allowable 
bending radius of the cable/tube to be installed.

Check the allowable bending radius recommended by 
the cable/tube manufacturer (for repeated bending).

Refer to the following guideline.

Cable with shield      = Max. cable outer diameter × 8
Cable without shield = Max. cable outer diameter × 6
Tube                          = Max. tube outer diameter × 9

Select a support member bending radius 

greater than the allowable bending radius of 

the cable/tube.

Allowable bending radius of cable/tube

Determination of support member bending radius

Allowable bending

radius of cable/tube

Support member

bending radius

Cable/tube mass

フラットベヤ/A3(420*297)

Содержание FLATVEYOR FVZP20D13N01SM2R070C1

Страница 1: ...TSUBAKI NEW FLATVEYOR ZP Type Hose and Cable Carrier System...

Страница 2: ...nding function added Flatveyor Tsubaki Flat cable competitor Flatveyor Tsubaki Flat cable competitor Sag comparison Bounce comparison The support member reduces sag in the unsupported length section a...

Страница 3: ...sound insulation effect of the integrated support member tubes reduce noise Products are available in black or white Tsubaki has developed an original openable tube that features excellent flexibilit...

Страница 4: ...by flat cables Structure Part name Material Function Support member This supports the cable tube and reduces sag Like cable carriers it also maintains the bending radius This is integrated in support...

Страница 5: ...ber structure reduces generation of wear debris PVC 2 Openable tube This tube stores a cable or tube Up to eight tubes can be selected Each openable tube is welded together PVC 3 Cap This prevents the...

Страница 6: ...e is 4 mm or less 11 or less 13 mm or less Cross section dimensions Basic specification A A arrow view 1 openable tube 2 openable tubes 3 openable tubes 4 openable tubes 5 openable tubes 6 openable tu...

Страница 7: ...ces for support member Clamp 3 mm Spacer Installation dimensions 1 Openable tubes and support member tubes are deformed into an oval shape at bends and other sections resulting in dimensional changes...

Страница 8: ...N01 to N08 Notes 1 70 mm FVZP26D13N01SM2R100C1 100 mm FVZP26D13N01SM2R130C1 2 FVZP26D13N02SM2R100C1 FVZP26D13N02SM2R130C1 3 FVZP26D13N03SM2R100C1 FVZP26D13N03SM2R130C1 4 FVZP26D13N04SM2R100C1 FVZP26D...

Страница 9: ...ion Flatveyor Closing tool FVZP D13 AST FVZP20D13N04SM2R070C1 50L Quantity 1 2 Unit PC SET Example of order for two FVZP20D13N04SM2R070C1 having 50 links and one closing tool Support member bending ra...

Страница 10: ...ference information Determine the cable tube arrangement and required number of openable tubes After they have been determined check the required space width Required number of openable tubes 3 Requir...

Страница 11: ...H 23 2K 2CL P Number of support member links Fixed end Moving end Travel length S Clamp length CL Leeway length K Mounting height H Support member bending radius R R 70 100 130 S H K P CL Travel lengt...

Страница 12: ...l length m S Travel length m 0 1 2 1 0 1 0 0 5 1 1 1 1 51 6 0 34 0 9 0 65 0 87 0 1 2 1 0 1 0 0 5 1 1 15 1 51 6 0 9 0 68 0 42 0 87 S Travel length m S Travel length m 0 1 2 1 0 1 0 0 5 11 05 1 51 6 0 9...

Страница 13: ...85 1 01 4 openable tubes Unsupported length m 0 1 2 1 1 0 62 1 09 2 openable tubes Unsupported length m S Travel length m 0 1 2 1 0 1 0 0 5 1 1 13 1 5 1 8 1 0 66 0 34 1 09 1 openable tube Unsupported...

Страница 14: ...e that section A is correctly overlapped around the entire length of the Flatveyor as shown in the figure above Temporarily tighten the end of the openable tube by hand 3 4 Close the locking part from...

Страница 15: ...hown in 1 Ensure that the locking part of the openable tube is properly closed Check that the bending section of the Flatveyor is not tilted and that the unsupported length is not twisted 3 4 Open Inc...

Страница 16: ...at angle 1 2 Welded end When installing multiple cables or tubes in a single openable tube install by keeping the cables or tubes aligned Installing cables while they are twisted could cause prematur...

Страница 17: ...in a direction other than the bending direction Bending in this state could damage the support member Do not install any object that could interfere with the inner circumference of the Flatveyor Suita...

Страница 18: ...ng radius R 2 Flatveyor damaged due to age related deterioration etc The following abnormal conditions may also occur as Flatveyors deteriorate over time Tearing of openable tube Breakage of support m...

Страница 19: ...described in the catalog instruction manual or similar Instruction manual or similar includes documentation specially provided to Customer 3 Inappropriate disassembly modification alteration or proces...

Страница 20: ...specifications in this catalog are subject to change without notice Catalog No KE2203 2022 09 TSUBAKIMOTO CHAIN CO The Tsubaki Eco Link logo is used only on products that satisfy the standards for env...