4.  Cautions When Handling 

Pretension and sag may appear in the free span depending on the application. However, if selected within Tsubaki’s 
performance graph then there will be no problems with use. 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Machine travel end installation height (H’) should be 

Cableveyor height H + (10-30). 

2.  Cableveyor installation space (h) should be H + 100. 
3.  Install a guide rail. 
4.  The difference (

İ

) in the travel end and fixed end 

bracket attachment faces should be less than 6mm.   

5.  Use travel cables/hoses with excellent bending and 

wear properties. 

6.  Avoid using wire plate jackets as they damage easily. 

 

7.  Cables/hoses wear easily when used stacked onto 

of one another. Lay horizontally or use horizontal 
dividers. 

8.  Set cables and hoses in the Cableveyor so that they 

have some play, and clamp both ends. 

9.  Remove foreign matter from guide rails, as it may 

cause damage. 

10. The following are shipped unassembled and will 

require assembly when installing the Cableveyor. 

z

 Arms 

z

 Dividers 

z

 Brackets 

*Plastic brackets will be delivered assembled to the 
Cableveyor 

 

 
 
 

*For more information, please see the Tsubaki Cableveyor catalog. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Issued October 1, 2012    ©Tsubakimoto Chain Co.

 

50mm or over 

50mm or over 

Moving end bracket 

Fixed end bracket 