4. Cautions When Handling
Pretension and sag may appear in the free span depending on the application. However, if selected within Tsubaki’s
performance graph then there will be no problems with use.
1. Machine travel end installation height (H’) should be
Cableveyor height H + (10-30).
2. Cableveyor installation space (h) should be H + 100.
3. Install a guide rail.
4. The difference (
İ
) in the travel end and fixed end
bracket attachment faces should be less than 6mm.
5. Use travel cables/hoses with excellent bending and
wear properties.
6. Avoid using wire plate jackets as they damage easily.
7. Cables/hoses wear easily when used stacked onto
of one another. Lay horizontally or use horizontal
dividers.
8. Set cables and hoses in the Cableveyor so that they
have some play, and clamp both ends.
9. Remove foreign matter from guide rails, as it may
cause damage.
10. The following are shipped unassembled and will
require assembly when installing the Cableveyor.
z
Arms
z
Dividers
z
Brackets
*Plastic brackets will be delivered assembled to the
Cableveyor
*For more information, please see the Tsubaki Cableveyor catalog.
Issued October 1, 2012 ©Tsubakimoto Chain Co.
50mm or over
50mm or over
Moving end bracket
Fixed end bracket
Guide rail