25
26
1. Install the clamp-calibration plate (1
0
D) from the spare parts kit in the clamp.
Clamp jaws should remain parallel.
2. Place the digital protractor on the calibration plate, along the axis of rotation of the clamp and
zero it.
3. Rotate the pivot-arm with clamp and repeat the measurements. If the value is more than 0.3°,
loosen screws (1) and use the arms to adjust the angle 1/2 the previously measured difference.
Holding this value, tighten the screws.
1
1
1.
2.
3.
D
igital protractor reference plane horizontal calibration
1. Mount the digital protractor on the pivot-arm and zero it.
2. Place the digital protractor in the location shown below (the flat just above the pivot-arm tension
adjuster). If the deviation is more than 0.3°, slightly loosen the adjusting screw with a 2mm
allen wrench. While holding by the hand from the bottom, adjust the angle using the digital protractor,
then tighten the upper adjustment screw.
1.
2.
3.
A
djustment of the rack-and-pinion mechanism
1. Using the 2mm allen wrench (1
0
A) from the spare parts kit, adjust the pinch screws 1 and 2,
as shown below. Adjust to minimize free up and down movement of the rack-and-pinion lift.
Changing the angle by turning the main thumbscrew should have slight resistance.
2. Using the 2mm allen wrench (1
0
A) from the spare parts kit, adjust screws 3 and 4 to optimize
the main thumbscrew preload.
1
2
3
4
1.
2.
D
igital protractor reference plane parallel calibration
*Perform after clamp angle calibration
1
. Place the digital protractor on the system stand and zero it. Next, set the protractor on a reference
plane (as illustrated below), and if the value exceeds 0.3° make an adjustment as needed.
1.
C
alibration of the built-in angle gauge
1. Lower the abrasive holder so that the guide bar rests at the hinge unit (see illustration).
Loosen the screw holding the arrow of mechanical protractor with 2mm allen wrench, and
adjust the arrow to indicate a 36° angle (illustration). In this position of the abrasive holder,
the angle is 36° by design.
2.
2. With the 2mm allen key. (1
0
A) from the spare parts kit, set the angle of the reference plane using
the adjustment screws.
Содержание K03
Страница 2: ...1 2 3 4 5 6 7 8 3 3 4 5 5 8 10 13 ENGLISH 16 PAGE...
Страница 4: ...5 6 4 1 1 10E 2 5 10F 3 2 1 5 10F 2 1 2 5 1 2 1 2 1 2 3 4 5 2 1 1 2 1 2...
Страница 5: ...7 8 1 2 1 2 1 2 4 16 10G 4 6 12 6 2...
Страница 6: ...9 10 3 4 1 5 2 5 7 0 3 1 1 2 1 3 10 1 2 3 2 1 2 10 1 2...
Страница 8: ...8 https tsprof com help warranty 1 1 5 service tsprof com 13 14 426065 10 80 405...