P a g e
|
40
PAM1 MK2
User Handbook Issue 1
2.16.3
Start, Stop and Reset Triggers
In order that
Loudness
measurement can be targeted towards specific programme content,
PAM1
is equipped with the ability to
Start
and
Stop
(pause) measurement cycles. These
functions can either be triggered manually from the on screen button or from a
GPI
via the
D9
connector at the rear of the unit.
The action of restarting measurement after a ‘stop’ is executed recommences calculation of
Loudness
from the previous value or values. This methodology ensures that programme
loudness measurement can be achieved outside of scheduled interruptions such as
commercial
breaks
or
announcements
. A means to integrate this could be to use
studio
or
playout
automation
to start/stop measurement via the
GPI
.
The
Reset
button discards any previously measured values enabling a new calculation to begin
once the
Start
button is activated once more.
2.16.4
Histogram Display and Integration Settings
The
Display
button within the
Loudness Setup
menu provides access to three integration modes
by which the resultant loudness level can be displayed as either a numerical value, moving line or
via the
Histogram
.
The sample for all Loudness measurement is set internally at 400ms. The 3 modes of display are
as follows:
A
3 Second
sliding window.
Integrated Measurement
over the entire duration of any clip/programme. Control achieved via
the Start/Stop/Reset buttons (soft or GPI)
Gated:
Similar to Integrated except that any sample lower than the -10dB gating level is
discarded.