Tsino-Dynatron Electrical Technology (Beijing) Co., Ltd.
2) Brake Chopper switched on Voltage
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
145
0x2085
Brake Chopper
switched on
Voltage of the
drive
mV
0~2147483647
100
Read only
Parameter description:
This parameter has been set by the manufacturer. Users can only view but not
modify it.
User permission:
User/Engineer.
Parameter permission:
Read only
Motor brake activated
7.5.2
The motor braking function is only applicable to servo motors with electromagnetic brake. This function can
guarantee that mechanical loads will not move due to gravity or external forces when power off.
Number
Index
Name
Unit
Setting range
Default
value
Effective
time
39
0x203C
Motor Brake
Control
-
0x00000000~0x01010001 0x01010001
Restart
Byte0: Motor brake enabling switch
0x00-Disable motor brake detection function;
0x01-Enable motor brake detection function.
Byte1: Reserved
Byte2: Motor brake braking delay control
0x00-Motor brake braking delay control is invalid;
0x01-Motor brake braking delay control is valid.
Byte3: Motor brake forced braking control
0x00-Motor brake forced braking control is invalid;
0x01-Motor brake forced braking control is valid.
Parameter Description:
User permission:
User/Engineer.
Parameter permission:
Read and Write
119
Содержание EtherCAT CoolDrive RC Series
Страница 1: ...Updated on Update summary Updated version Version number D3 ...
Страница 17: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC3 2 3 2 7 ...
Страница 18: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC4 2 3 3 8 ...
Страница 19: ...Tsino Dynatron Electrical Technology Beijing Co Ltd 9 ...
Страница 20: ...Tsino Dynatron Electrical Technology Beijing Co Ltd Dimension Drawing of RC6 2 3 4 1 ...