Rear Controls & Functions

A

B

C

E

D

¨

If you are not sure about how much

power your equipment draws, see

accompanying table, “Load Ratings

for Typical Equipment”

¨

See p. 8 for more information

about Remote UPS Access

Rear Controls & Functions    

3

© Copyright—2000 TSi Power Corporation.  All rights reserved.

TSi Power’s ongoing product improvement process makes specifications subject to change.

Other company’s  product names herein are for identification purposes only and may be trademarks of their respective companies.

A

UPS Output Receptacles

Outlets for the equipment to be supported by the UPS.  The power
drawn from these receptacles should not exceed 360 watts for UPS-550B
and 500 watts for UPS-720B.

B

     

AC Fuse

Replace only with same type and rating.

C

AC IN Socket

AC mains power input connector.  International standard CCE-22 type.

D

Alarm Interface 

(some models)

Connects to a file server, PC or workstation for UPS monitoring.

E

Remote Control 

(some models)

Dual RJ-11 phone and modem connectors for remote access.  Connect
the incoming phone line to LINE connector, other phone equipment
(telephone, fax, modem etc.) to the MODEM connector.

U P S

O U T P U T

CAUTION

TO REDUCE THE 
RISK OF FIRE OR 
ELECTRIC SHOCK, 
INSTALL IN A 
TEMPERATURE 
AND HUMIDITY 
CONTROLLED 
AREA FREE OF 
CONDUCTIVE 
CONTAMINANTS.

WARNING

THIS UPS RECEIVES POWER FROM MORE THAN 
ONE SOURCE—DISCONNECTION OF THE AC 
SOURCE AND THE DC SOURCE IS REQUIRED TO 
DE-ENERGIZE THIS UNIT BEFORE SERVICING.
DO NOT REMOVE COVER. NO USER SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED 
PERSONNEL.
HAZARDOUS LIVE PARTS INSIDE THIS UPS ARE 
ENERGIZED FROM THE BATTERY SUPPLY EVEN 
WHEN THE INPUT AC POWER IS DISCONNECTED.

AC

FUSE

WARNING

FOR CONTINUED PROTECTION 
AGAINST FIRE, REPLACE ONLY WITH 
SAME TYPE AND RATING OF FUSE

AC IN

125V 7A

UNINTERRUPTIBLE
POWER  SUPPLY

AC INPUT:
UPS OUTPUT:
DC IN/OUTPUT:

SERIAL NO.

MADE IN U.S.A.

TO EXT-5000

CAUTION

TURN OFF POWER 
SWITCH DURING 
BATTERY EXTEN- 
SION CONNECTION. 
FOR DISCONNECT 
USE ONLY.  NOT
INTENDED FOR
CURRENT IN-
TERRUPTION.

MODEM

LINE

B1 B2 B3 B4

REMOTE CONTROL

BAUD

RATE

RS-232

INTERFACE

ALARM

INTERFACE

UPS-7200

120V, 60HZ, 7A MAX, P.F.=1
120V, 60HZ, 4.2A MAX, P.F.=1
24V, 30A MAX

F U

 S E   F U

 S E

     F U

  S E

5

4

3

2

1

9

8

7

6

5

4

3

2

1

9

8

7

6

ON

1

2

3

4

Содержание UPS-550B

Страница 1: ...POWER CORPORATION 1103 West Pierce Avenue Antigo WI 30071 USA Phone 715 623 0636 FAX 715 623 2426 Internet www tsipower com e mail sales tsipower com Copyright 2000 TSi Power Corporation All rights re...

Страница 2: ...battery supply inside the UPS is 24 volts Maximum Operating Ambient Temperature for the UPS and Battery Extension Unit is 40 degrees Celsius When you are using the rack cabinet or wall mounting kits p...

Страница 3: ...UPS Access 8 Typical Holdup Times 10 Trouble shooting and Maintenance 11 UPS Technical Specifications 12 Installation Procedure for Mounting Kits 13 i Copyright 2000 TSi Power Corporation All rights...

Страница 4: ...the large power on off switch in the front of the UPS and turn the UPS on All your equipment hooked up to the UPS should now be ready to power up Congratulations You ve already taken a large step tow...

Страница 5: ...rging Light This red light is on when battery is being charged F Inverter On Light This yellow light blinks when AC power is abnormal and UPS is operating on battery G Remote Mode Light some models Th...

Страница 6: ...odem connectors for remote access Connect the incoming phone line to LINE connector other phone equipment telephone fax modem etc to the MODEM connector U P S O U T P U T CAUTION TOREDUCETHE RISKOFFIR...

Страница 7: ...uch more Its architecture is that of a standby UPS or off line UPS whose inverter is only activated when the line AC becomes irregular This has the advantage of lower cost and greater reliability sinc...

Страница 8: ...e on indicating that the battery is being recharged This is normal 5 As a test you may simulate a power outage by unplugging the UPS power cord from the AC outlet All your equipment connected to the U...

Страница 9: ...ours 11 When an overload occurs and the UPS shuts off you must remove the excess load and reset the UPS by turning it off and then on before the UPS will resume proper operation Your UPS will hold up...

Страница 10: ...S A positive pulse 5V or higher and lasting longer than 1 4 sec will shut down the UPS when it is running on battery power Open Collector Output from UPS Normally open this transistor switch will clos...

Страница 11: ...within this time The UPS will not interfere with the modem or telephone It may take about a minute after the UPS is turned on for the first time before the MODE switch becomes operational U P S O U T...

Страница 12: ...ou need to access the remote PC you would dial the UPS turn on the remote PC and let your home modem and remote modem establish a connection When finished you can hang up and power to the PC will be t...

Страница 13: ...y be trademarks of their respective companies Typical Holdup Times A typical desktop PC or Macintosh draws between 200 and 300 watts The table below shows some typical holdup times with a computer loa...

Страница 14: ...attempt to repair the UPS High voltages are present and there are no user servicable parts inside Repairs can be performed only at the factory or at an authorized repair centers by qualified personnel...

Страница 15: ...ransfer back to AC Transfer Time 1 millisecond phase locked to the AC Two long life leak proof sealed lead calcium batteries each rated at 12VDC 7A h provide 168VA h of capacity Typical recharging tim...

Страница 16: ...ssembled properly with the equipment mounting rails securely installed at the intended location This should be either in the front or rear of the cabinet for MK 5000A or in the center of the cabinet f...

Страница 17: ...he desired height Fasten the screws B provided with the kit through the mounting bracket into the rails using the clip nuts previously installed Wall Mounting for MK 5000C only 1 Make sure that the wa...

Страница 18: ...IS NOT LIABLE FOR CONSEQUENTIAL DAMAGES THIS WAR RANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Excluding batteries Battery manufacturer s war...

Отзывы: