Troubleshooting
Detailed troubleshooting and frequently asked questions can be
found at
https://tsi.com/resources/airassure-iaq-monitors-faqs/
The table below lists some symptoms, possible causes, and
recommended solutions for common problems encountered with the
AirAssure
™ Indoor Air Quality Monitor.
Possible Cause
Corrective Action
The AirAssure
™
IAQ monitor does not turn on
Bad Power
Connection
Check all power connections from the outside of the
Enclosure to the Monitor. If you are powering with
24 VAC, confirm that the proper voltage is present or
try powering with the USB power supply. If using the
USB power supply, try a different power supply
and/or cable.
The AirAssure
™
IAQ monitor has no data on the TSI
®
Cloud
Check the LED
status bar
If the device is not connecting (solid blue after
2 minutes), check your local 2.4 GHz Wi-Fi
®
connection strength with another device like a phone.
If there is a good signal, follow the directions in the
section to check the connection.
LED
Wi-Fi
Cloud
Pulse Yellow
Set up Mode
Pulse White
Connecting
Pulse Blue
Connected
Connecting
Solid Blue
Connected
Connected
Solid White
No connection
No connection
Содержание AIRASSURE 8144
Страница 6: ...iv Appendix A Specifications 39 Appendix B Status Flags and Error Codes 43 Examples 46 ...
Страница 35: ...Operation 25 ...
Страница 36: ...26 Chapter 3 This page intentionally left blank ...
Страница 44: ...34 Chapter 4 This page intentionally left blank ...
Страница 48: ...38 Chapter 5 This page intentionally left blank ...
Страница 52: ...42 Appendix A This page intentionally left blank ...
Страница 57: ......