![TSI Instruments 854033 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/tsi-instruments/854033/854033_quick-start-manual_1178143003.webp)
-3-
3. Mount the Heater Power Supply onto the upper DIN
Rail by hanging the top bracket clips on the DIN Rail
and snapping the bottom back into place. Attach the
Mains Power Cord, looping the cord as shown.
4. Install the thermostat onto the lower DIN Rail and
plug thermostat wire into
the “+” (Gray) DIN Rail
Power Connector.
5. Install the Gray Power Connector and Green Ground
Connector onto the DIN Rail next to the Thermostat.
Ensure Power Connector (Gray) is to the left of the
Ground Connector and next to the Thermostat.
6. Install the Heater onto the DIN Rail and Plug into the
two Phoenix Connectors just installed to the right of
the Thermostat.
7. Plug the remaining Thermostat wire into the
”+” side
of the Heater Connector (left side of connector,
Gray) as shown.
DO NOT
PLUG THE THERMOSTAT
WIRES INTO THE GREEN/YELLOW
PHOENIX GROUND CONTACTS
THE THERMOSTAT
MUST
PROVIDE
POWER TO THE HEATER. BYPASSING
THE THERMOSTAT, OR PLUGGING
THE HEATER DIRECTLY INTO THE
POWER SIDE OF THE DIN RAIL, WILL
CAUSE THE HEATER TO RUN
CONSTANTLY AND MAY DAMAGE
EQUIPMENT AND LEAD TO
PREMATURE FAILURE(S).
8. Insert vent plugs into openings to help keep heat
inside enclosure in cold environments. Twist covers
counter clockwise to remove. Hand-tighten after
inserting plug.