background image

SP Series Technical Manual 

 

- 17 - 

 

9. DRAWING 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Parts List 

Содержание SP Series

Страница 1: ...Water proof scale TECHNICAL MANUAL ...

Страница 2: ...SP Series Technical Manual 1 ...

Страница 3: ...FICATIONS 5 DIMENSION 5 4 INSTALLATION 7 5 PARTS DESCRIPTION 9 6 OPERATION 12 1 Power ON OFF 12 2 Zero 12 3 Tare 12 4 Unit Quantity 12 5 Commodities without weighing 13 6 Backlight 13 7 Auto Power Off 13 7 PARAMETER 14 8 CALIBRATION 16 9 DRAWING 17 PARTS NAME 18 10 ERROR CODE 20 ...

Страница 4: ...es from the battery compartment to avoid leakage Avoid stack materials on the scales when scale is not in use Avoid unsuitable tables The tables or floor must be rigid and not vibrate Do not place near vibrating machinery Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not mix the type of batteries Replace all the batteries at th...

Страница 5: ... is suitable for sanitary applications general weighing price computing and accumulation applications IP65 waterproof technology ABS Plastic housing Super low power consumption Optional options for dry cell battery and rechargeable battery 15mm LCD with white LED back light display 20 mechanical switches ...

Страница 6: ...kg 15kg Division 1g 2g 5g External Resolution 3000 6000 Dual Display 15mm LCD x 3 display with White back light Pan Size 200mm x 260mm Keypad 20 mechanical keys Operate Temperature 0 C 40 C 32 F 104 F Power Adaptor 12V 500mA Battery 6V 3 2 AH Internal Counts Up to 60000 Weight Lead Acid 4 2 kg ...

Страница 7: ...V 0 2 mV V Excitation Voltage 18 VDC IP Level IP65 Material Aluminum Alloy Cable Φ 3 8mm four core shield Input Resistance 409Ω 6Ω Out put Resistance 350 Ω 3Ω Temperature Range 10 C 40 C Safe overload 150 R C Ultimate overload 300 R C Repeatability 0 02 R O Creep 0 02 R O 20min Zero Balance 0 2 mV V Weight 200g ...

Страница 8: ...en you change the location Charging Battery To charge the battery insert the adaptor pin to jack jack is locating below the scale Adaptor simply plug into the mains power The scale no needs to be turned on The battery should be charged for 12 hours for full capacity Left side of the display there is an LED to indicate the status of battery charging When the scale is plugged into the mains power th...

Страница 9: ... the scale Adaptor connects into your AC power socket Pluggable equipment must be installed near an easily accessible socket outlet with a protective ground earth contact Turn on the On Off key If you want to turn off press the key again Display will be show the version number and will be starting self checking After self checking display will be come to normal weighing mode Warm up time of 15 min...

Страница 10: ...SP Series Technical Manual 9 5 PARTS DESCRIPTION Overall View Sealing Ring Breathable knob Adaptor jack Adaptor Pan Leveling Feet Key board Spirit Level ...

Страница 11: ...power On Off Set the display to zero Enter the clear tare weights Storing the current weight as tare value to PLU keys Quantity key use for with out weighing Clear incorrect entries and error conditions to Numeric Keys Enter to individual unit weights and the present tare ...

Страница 12: ...SP Series Technical Manual 11 Display Rear Display Display Weight STABLE Stability Display ZERO Zero display NET Net Weight BATT Low Battery Display Unit Price kg 100g Current unit weight ...

Страница 13: ...ance to zero any time by pressing key and therefore ensure that the weighing starts at zero 3 Tare The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed Load weight on the pan Press key Zero is displayed and tare is subtracted Remove weight from the platform Tared weight is displayed It can set on...

Страница 14: ...n on back light full time Off Back light turn off Press and hold key 3 seconds Display will be shown Press key or press 1 2 3 keys to change the mode to auto on off Then press to confirm 7 Auto Power Off SP scales have automatic power turn off function Turn on the scale press the key during the start up Display will be shown Press to change option and then press to confirm Options Of 0 To set auto...

Страница 15: ...y one Enter the Selected Menu Press it can confirm which will be shown displayed Note Before enter into the menu press the calibration switch to operate the function Switch is locating near the battery Parameter Block Menu Description F0 cal Calibration F1 res 3 000 Set Resolution 6000 dual F2cap 3 kg Set Scale Capacity 6 kg 15 kg 3 0 kg F3 pdesl 0 To set the weight decimal point 0 0 0 00 0 000 F4...

Страница 16: ... zero range Options 0 5 d 1d 2d 4 d F8 scsiue tare s tare on Turn On re tare function it can continue the tare operations s tare off Turn off re tare function it can do only one time F9 p unit Unit_2 off No function F10 counts Internal counts F11 spd Speed 7 5 Set AD speed Speed 15 Speed 3 0 Speed 6 0 F12 gra Grav To set local gravity F13 pin P1 Enter the new password P 2 Re enter the new password...

Страница 17: ... near the battery Press to confirm and display will be shown After stable press to confirm and display will be shown Shown current calibration weight value If necessary press to change the value and keep the calibration weight on the platform After stable indicator on press key to confirm Display will be come back to the menu Incase display will show any error message or incorrect measurement repe...

Страница 18: ...SP Series Technical Manual 17 9 DRAWING Parts List ...

Страница 19: ...r bracket 1 16 M6 Washer 4 17 Rubber Seal 1 18 Rear Display PCB 1 19 Breathable Film 20 Bottom Cover 1 21 Adaptor Rubber Cap 1 22 Adaptor Jack 1 23 Seal Rubber 2 1 24 Rechargeable battery 1 25 Film Fix Circle 2 1 26 Film 1 27 Key board Overlay 1 28 Front Display Overlay 1 29 M4 16 Hexagon Screw 4 30 M4 Hexagon Nuts 4 31 AD seal Box 1 32 M3 10 Star screw 18 33 Main PCB 1 34 Calibration switch 1 35 ...

Страница 20: ...SP Series Technical Manual 19 42 Battery box cover fixer2 3 43 M4 13 Star Screw 5 44 Sealed Washer 8 45 Washer Cover 8 46 Foot fixer 4 47 Foot 4 ...

Страница 21: ...Key board error Check the keys and connecter Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Check the load cell and connecters Err 17 Tare out of range Remove the load and restart scale again ol Over range Remove the load Re calibrate...

Страница 22: ... The TSCALE products Medical Scale Counting Scale Tabletop Scale Retail Scale Precision Scale Platform Scale Weighing Indicator Crane Scale Floor and Pallet Scale Accessory Software TSCALE has its manufacturing unit in Kunshan China ISO 9001 certified company OEM ODM partner more than 20 products have OIML certifications from Holland s NMI and Denmark s Delta TScale Electronics Mfg Kunshan Co Ltd ...