7
Safety, Installation, and Operations Manual
©2020 TSC PowerHome All rights reserved. Contents subject to change without notice. TSC-MAN-0001 Rev 02, 06-2020
High Performance Solar
good electrical bonding path.
The #10-32 assembly attachment screw must be tightened between 20-25 inch-pound. A 10 AWG bare
copper ground conductor must be attached to the ground lug using the stainless-steel set screw provided
by the lug manufacturer. Tighten the set screw between 10-15 inch-pound to ensure a strong mechanical
and electrical bond.
Recommended stainless steel hardware and assembly:
Grounding Hole A
#10-32 Hex Headed Screw SS
#10-32 Hex Nut SS
#10 Tooth Lock Washer SS
#10 Flat Washer SS
3.2 Non Grid-Tied Applications
y
Contact TSC for appropriate grounding guidelines.
4.0 Module Mounting
The TSC Corporation PowerXT
®
Warranty is contingent upon modules being mounted in accordance to the
requirements described in this section.
4.1 Site Considerations
TSC modules should be mounted in locations that meet the following requirements.
y
Module should not be mounted in locations where it will be in direct contact with salt water.
y
When choosing a site, avoid obstructions that could cast shadows on the modules as much as possible.
4.2 Mechanical Installation
TSC module mounting configurations must meet the following requirements:
y
Do not remove or alter the module frame. Creating additional mounting holes may damage the module and
reduce the strength of the frame.
y
For roof mounting, the modules should be mounted over a fire-resistant covering rated for the application.
y
Clearance of 7 mm or more between modules is required to allow for thermal expansion of the frames.
y
Clearance of 100 mm or more is recommended between the modules and the rooftop or nearest surface.
y
Always keep the back surface of the module free from any foreign objects or structural elements which could