Safety, Installation, and Operations Manual
©2020 TSC PowerHome All rights reserved. Contents subject to change without notice. TSC-MAN-0001 Rev 02, 06-2020
High Performance Solar
2.1 FIRE RATING AND SAFETY
y
TSC PowerXT
®
residential solar modules are UL 61730 Fire Type 1 rated and IEC 61730 Application Class II.
The solar modules have been certified by an independent third-party testing laboratory.
y
Refer to your local authority for guidelines and requirements for building or structural fire safety.
y
The roof construction and installation may affect the fire safety of a building: improper installation may
contribute to hazards in the event of fire.
y
It may be necessary to use components such as ground fault circuit breakers, fuses and circuit breakers.
y
Do not use modules near equipment or locations where flammable gases can be generated or can collect.
Artificially concentrated sunlight shall not be directed onto the module.
3.0 ELECTRICAL INSTALLATION
Caution: Avoid all electrical hazards when installing, wiring, operating, and maintaining a module
or module array. Refer to Section 2 for more information
y
Refer to all applicable federal, state, and local codes for proper wiring and fusing practices.
y
The system must be installed, commissioned and maintained by a licensed electrician unless local electrical
codes determine otherwise.
y
Contact with DC voltage is potentially hazardous.
y
Do not use modules of different electrical or physical configurations in the same DC string or inverter.
y
For field connections, Solaria recommends that all connecting cables be double insulated flexible copper
(Cu) conductors with a minimum rating of 90°C. The cable size should be determined by the applicable codes
but is recommended that this be no less than 4mm² or 12AWG. The connectors must be compatible with the
factory installed connectors on Solaria panels (MC4 design) or as specified in the product datasheet.
Series
Connection: The modules may be wired in series to produce the desired voltage output. Do not exceed the
maximum system voltage indicated on the module label.
y
Parallel Connection: The modules may be combined in parallel to produce the desired current output provided
that each series string or module is fused prior to combining with other strings. The maximum fuse size
allowed is noted on the module label.
y
Connection cables and wiring shall be supported with plastic or rubber cable ties and clips to the module
support structures. Metal clips specifically designed to be used in solar applications are allowed when used
in accordance with the manufacturer’s instructions. Module junction boxes and metal cable ties should not be
used to support cables and wiring.
y
Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current
and/or voltage than reported at Standard Test Conditions (STC). Unless specifically dictated by federal, state
or local codes, the values of Isc and Voc marked on this module should be multiplied by a factor of 1.25 when
determining component voltage ratings, conductor capacities, fuse sizes, and size of controls connected to the