Recorder’s Functional Testing
Trial Recording.
Snap the Switch (position 1) to “Record” position.
When the recorder starts recording, the LED
(position 3) flashes five times. To stop the
recording, snap the Switch (position 1) to “Stop”
position. When the recorder stops recording, the
LED (position 3) flashes once. The duration of the
last flash can be a dozen seconds depending on
the recorder’s memory size. While recording, two
series of LED flashes show the battery charge and
free memory size (see Instructions on the shipped
CD for more details).
To play back the recording upload the recording
onto a hard drive with the help of “Rec Manager”
program (located on the shipped CD).
Rechargeable battery charging
Snap Switch (position 1) to “Stop” position.
Connect the recorder to USB-connector of the
PC. The charging starts. The device should be
charged for at least 4 hours (at the fully discharged
rechargeable battery). To control the charging
level, use “RecManager” program. Switch the
recorder off the PC.