3
1-2 Specification.
z
Power Input Voltage: DC +10V to +30V.
z
LAN: Auto-MDIX, 10/100 Mbps Auto-detecting.
z
RS-232: TX, RX, RTS, CTS, DTR, DSR, DCD, GND.
z
RS485 signal: differential 2 half-duplex wires (DATA+, DATA-).
z
RS422 signal: differential 4 full-duplex wires.(TX+,RX+,TX-,RX-)
z
Data Rate: 1200,2400,4800,9600,19200,38400,57600,115200,921600 K bps .
z
Parity: none, even, odd.
z
Data Bits: 5, 6, 7 or 8.
z
Stop Bits: 1, 1.5 or 2.
z
Protocol: TCP, IP, ARP, DHCP, Telnet, HTTP, UDP, ICMP
z
External switch: OFF OFF :TCP and VSP mode.
ON OFF : Option .
OFF ON :Option.
ON ON :Back to Factory.
z
Virtual-Com mode support RS232 TXD,RXD,GND.
RS422 TX+,TX-,RX+,RX-.
RS485 DATA+,DATA-.
z
Power supply: Screw terminal or DC jack.
z
Serial interface: +/-15 KV ESD.
z
RS422/485 interface: Surge, over current, over voltage protection.
z
Power consumption: 12V/140mA.
z
Operating
Temperature:-10 to 65 °C.
z
Humidity: 0~90% Non-Condensing.
z
Dimensions: 151(L)*75(W)*26(H) mm.