11
The default LAN Netmask is configured for a Class C address. This maybe reconfigured by the
user.
Gateway
Input the gateway IP address that can be allows users to access the serial server from internet.
DNS
Short for Domain Name System, an Internet service that translates domain names into IP
addresses. Because domain names are alphabetic, they're easier to remember. The Internet
however, is really based on IP addresses. Every time you use a domain name, therefore, a DNS
service must translate the name into the corresponding IP address.
Transmit timer:1~500 ms/Unit
Time interval to send out serial data char packet.
*The function main support serial data input to TRP-C37 RS232/422/485 port, if serial data
is a mass of serial data over 1K Byte ,Trying to adjust the Timer to 200ms.
Hear Beat: Disable /Enable
When Hear Beat enable, the TRP-C37 allows user open a TCP 5300 port, 10 sec interval to
send out data char packet that provides a easy way to ensure the communications between Host
PC Client and server devices.
Maximum Connection: 1~16
The function allows the user to configure the TRP-C37 in Server mode adjust 1~16 TCP client
host connections.
TCP Keep Alive: 1~7 /Minute
When TRP-C37 in Server mode, the TRP-C37 without data over the 1~7 Min setting value,
The TRP-C37 will be disconnect TCP.
When TRP-C37 in Client mode, the TRP-C37 without data over the 1~7 Min setting value,
The TRP-C37 will be reconnecting TCP.
New Password: 1234
It only accepts value from1000~9999 integer, if input the wrong password over 5 times, the
WEB-Page will lock until the TRP-C37 re-boot.
Firmware Version: ABC
AB: Suitable DSM utility version
C: Release Version
Example: If the firmware version is 351.
Please run the DSM utility is Version:3.5
Serial Port setting
Baud Rate: UART Speed from 1200,2400,4800,9600,19200,38400,57600,115200,921600 K bps
Data Bit: 5,6,7,8
Parity: Odd, Even, None
Stop Bits: 1, 1.5,2.
Flow Control: Xon/Xoff, Hardware, None
Submit