4
2-4. Reset Button
The reset button can be found between the switch and terminal block. To reset the unit manually
apply power, insert a small plastic tool, and press lightly depressing switch. The system will
reboot.
2-5. Dip Switches
A double DIP switch allows the TRP-C32S to be placed into default/ Loop Back/Factory/console
Mode.
When all these switches are moved into the ON position, theTRP-C32S enters console Mode,
allowing configuration of the TRP-C32S from a PC running a terminal program such as
Hyper-terminal. When the TRP-C32S enters console Mode, the console Mode screen will
appear in the Hyper-terminal program window
. The PC serial port configuration must be set
to 8-N-1 at 9600 baud rate.
When the DIP switches are switched to the ON OFF position, the TRP-C32S will work at internal
Loop back Mode, all data is sent back immediately.
When the DIP switches are switched to the OFF ON position, the TRP-C32S will revert to its
factory version firmware no matter what newer firmware has been upgraded.
When all of the DIP switches are switched back to the OFF position, the TRP-C32S will enter
default data Mode (RS-232, RS-422 or RS-485). Refer ,3
2-6. DB-9 Pin Configuration