background image

 

 

6. How to test TRP-C08D   

Trycom  Technology  Co.,Ltd  offers  test  utility,  this  is  utilities  may  help  user  to  demo  and  test 
TRP-C08D  fast  and  easily.  User  may  find  the  utilities  in  Trycom  support  CD  or  download  from 
Trycom web 

www.trycom.com.tw

 ,

 

direct to perform TRPCOM.exe from the directory. 

 

 

6-1 RS422 Loop Back Test 

 

Hardware wiring connection for RS422 loop test.   
 

 

Содержание TRP-C08D

Страница 1: ...ion in this manual is subject to change without notice to improve reliability design and function and does not represent a commitment on the part manufacturer No part of this manual may be reproduced...

Страница 2: ...a line Power and TXA RXA communication LED indicator Din Rail or panel mount Driver support Driver Support Android Windows 2000 WIN 7 WIN10 WIN11 and Linux 4 1 and Embedded Linux 5 5 1 2 Specification...

Страница 3: ...2 Hardware Description 2 1 Panel layout 2 2 LED Indictor PWR LED System is ready RXA LED COMA RS422 485 Receiving TXA LED COMA RS422 485 Transmitting...

Страница 4: ...s A null modem cable is required to make a connection between the PC COM port and the TRP C08D serial port 2 5 USB Connection The TRP C08D has a USB B Type connector which is fully compliant with USB...

Страница 5: ...ndshaking Flow Control must be set to RTS CTS during configuration Refer to the Pin out table for connections 2 9 USB Cable Wiring TRP C08D is true USB 2 0 specification it also supports USB V1 0 V1 1...

Страница 6: ...cessfully TRP C08D device detection can be confirmed by checking at the Device manager Check for High Speed USB MultiSerial Compound Device under Universal Serial Bus controllers and you will find Hig...

Страница 7: ...ilities may help user to demo and test TRP C08D fast and easily User may find the utilities in Trycom support CD or download from Trycom web www trycom com tw direct to perform TRPCOM exe from the dir...

Страница 8: ...Run the TRPCOM EXE utility STEP2 Click the Setting to set the com port and baud rate then press OK Please note COM2 is an example of COM port number the real COM number is assigned by user PC STEP3 Cl...

Страница 9: ...ce such as connecting TRP C28 send 01M instruction from the client side when the TRP C28 received command that will response 01TRPC28 indicates execution completed Step1 Run TRPCOM exe utility Step2 C...

Страница 10: ...Step3 Send command 01M and press Send button Step4 TRP C28 response received...

Страница 11: ...7 TRP C08D Application...

Отзывы: