Air and moisture in the refrigerant system have 

undesirable effects as below:   

Pressure in the system rises.

Operating current rises.

Cooling or heating efficiency drops.

Moisture  in  the  refrigerant  circuit  may

freeze and block capillary tubing.

Water may lead to corrosion of parts in the

refrigerant system.

Therefore,  the  indoor  units  and  the  pipes

between indoor and outdoor units must be leak 

tested  and  evacuated  to  remove  gas  and 

moisture from the system.

 

Gas leak check (Soap water method): 

Apply  soap  water  or  a  liquid  neutral 

detergent  on  the  indoor  unit  connections  or 

outdoor  unit  connections  by  a  soft  brush  to 

check  for  leakage  of  the  connecting  points  of 

the piping. If bubbles come out, the pipes have 

leakage. 

1. Air purging with vacuum pump

1) Completely  tighten  the  flare  nuts  of  the

indoor and outdoor units, confirm that both

the

 

2-way  and  3-way  valves  are  set  to  the

closed position.

2) Connect the charge hose with the push pin

of handle lo to the 3-way valves gas service

port.

3) Connect  the  charge  hose  of  handle  hi

connection to the vacuum pump. 

4)

Fully  open  the  handle  Lo  of  the  manifold

valve.

5)

Operate the vacuu

m

 pump to evacuate.

6)

Make evacuation for 30 minutes and check

whether  the  compound  meter  indicates

-0.1Mpa.  If  the  meter  does  not  indicate

-0.1Mpa  after  pumping  30  minutes,  it

should be pumped 20 minutes more. If the

pressure  can

t  achieve  -0.1Mpa  after

pumping 50 minutes, please check if there

are some leakage points.

Fully close the handle Lo valve of the manifold 

valve  and  stop  the  operation  of  the  vacuum 

pump. Confirm that the gauge needle does not 

move (approximately 5 minutes after turning off 

the vacuum pump). 

7) Turn the flare nut of the 3-way valves about

45

°

  counterclockwise  for  6  or  7seconds

after the gas

coming  out,  then  tighten  the  flare  nut  again. 

Make sure the pressure display in the pressure 

indicator  is  a  little  higher  than  the  atmosphere 

pressure.  Then  remove  the  charge  hose  from 

the 3 way valve. 

8) Fully open the 2 way valve and 3 way valve

and  securely  tighten  the  cap  of  the  3  way

valve.

2. Air purging by refrigerant

Procedure: 

1). Confirm that both the 2-way and 3-way valves 

are set to the closed position. 

2).  Connect  the  charge  set  and  a  charging 

cylinder to the service port of the 3-way valve.   

1

.4 Installation for the first time 

3

Содержание TC Series

Страница 1: ... CONDITIONING EQUIPMENT CO Prepared By Engineering R D Department Shiraz May 2017 INVERTER WALL MOUNTED SPLIT TC SERIES TRUST AIR CONDITIONING EQUIPMENT CO Prepared By Engineering R D Department Shiraz May 2017 ...

Страница 2: ...or many years 4 1 6 Re installation while the indoor unit need to be repaired 5 1 7 Re installation while the outdoor unit need to be repaired 6 1 Installation Details 1 1 1 Wrench torque sheet for installation 1 3 2 Display function 10 3 3 Main Protection 11 3 4 Operation Modes and Functions 12 3 Electronic function 10 3 1 Abbreviation 10 2 Operation Characteristics 9 ...

Страница 3: ...ld be selected according to the following specifications sheet Rated current of appliance Nominal cross sectional area mm 3 and 6 0 75 6 and 10 1 10 and 16 1 5 16 and 25 2 5 The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse an...

Страница 4: ... 3 8 Ф9 52 1 4 Ф6 35 5 10 25 15 TMST12HT1I3 66 i O 4SW1R1N1S 1 2 Ф12 7 1 4 Ф6 35 5 10 25 15 TMST18HT1I3 52 i O 4SW1R1N1S 1 2 Ф12 7 1 4 Ф6 35 5 20 30 15 TMST24HT1I3 55 i O 4SW1R1N1S 5 8 Ф15 9 3 8 Ф9 52 5 25 50 30 Caution The capacity test is based on the standard length and the maximum permissive length is based on the system reliability 1 3 Pipe length and the elevation 2 ...

Страница 5: ... to the vacuum pump 4 Fully open the handle Lo of the manifold valve 5 Operate the vacuum pump to evacuate 6 Make evacuation for 30 minutes and check whether the compound meter indicates 0 1Mpa If the meter does not indicate 0 1Mpa after pumping 30 minutes it should be pumped 20 minutes more If the pressure can t achieve 0 1Mpa after pumping 50 minutes please check if there are some leakage points...

Страница 6: ... the vacuum pump to the valve at the bottom of the cylinder If the refrigerant is R410A make the cylinder bottom up to ensure the liquid charge 2 Purge the air from the charge hose Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air be careful of the liquid refrigerant 3 Put the charging cylinder onto the electronic scale and record the weight ...

Страница 7: ...r purging of the charge hose Open the handle Lo valve of the manifold valve slightly to purge air from the charge hose for 5 seconds and then close it quickly 4 Set the 2 way valve to the close position 5 Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0 1MPa 6 Set the 3 way valve to the closed position immediately Do this quickly so that the gauge ends up ind...

Страница 8: ...e hose to the charging cylinder open the 2 way valve and the 3 way valve Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder If the refrigerant is R410A make the cylinder bottom up to ensure liquid charge 2 Purge the air from the charge hose Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge t...

Страница 9: ...port Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage 7 ...

Страница 10: ...ove conditions certain safety protection features may come into operation and cause the unit to operate abnormally 2 The room relative humidity should be less than 80 If the air conditioner operates beyond this figure the surface of the air conditioner may attract condensation Please set the vertical air flow louver to its maximum angle vertically to the floor and set HIGH fan mode 3 The optimum p...

Страница 11: ...ration Dispalys when anti cold air feature is activated under heating mode Dispalys during self clean operation if aplicable Dispalys under 8 heating operation if aplicable Optional According to the operation mode the indicator displays different colour Under Cool or Dry mode it displays as cool colour Under Heat mode it displays as warm colour if aplicable Energy saving display Displays when the ...

Страница 12: ...fan will open 7s later If the unit runs in heating mode the indoor fan will be also controlled by anti cold wind function 3 3 7 Compressor preheating functions Preheating permitting condition When T4 outdoor ambient temperature 3 C the preheating function will be activated 3 3 8 Sensor protection at open circuit and breaking disconnection When there s only one temperature sensor in malfunction the...

Страница 13: ...H H B C M M M Z D M M M E F L L L D G L L L H I T1 Td F L L L L D H H H H G M M M M Z The auto fan acts as below rules a b c d T 1 e Resume Off Decrease Hold Increase 3 4 Operation Modes and Functions 3 4 1 Fan mode 1 Outdoor fan and compressor stop 2 Temperature setting function is disabled and no setting temperature is displayed 3 Indoor fan can be set to high med low auto 4 The louver operates ...

Страница 14: ...F L L L D G L L L H I T1 Td F L L L L D H H H H G M M M M Z Auto fan action in heating mode a b c d T 1 e lighted Will be displayed If any one of the following items is satisfied the defrosting will finish and the machine will turn to normal heating mode T3 rises to be higher than TCDE1 T3 keeps to be higher than TCDE2 for 80 seconds The machine has run for 15 minutes in defrosting mode 3 4 2 5 Ev...

Страница 15: ...g temperature can be changed between 17 C 30 C In auto mode the machine will choose cooling heating or fan only mode according to ΔT ΔT T1 Ts 3 4 5 Drying mode Indoor fan speed is fixed at breeze and can t be changed The louver angle is the same as in cooling mode All protections are active and the same as that 3 4 7 Timer function 3 4 7 1 Timing range is 24 hours 3 4 7 2 Timer on The machine will...

Страница 16: ...erature decreases 1 be higher than 17 every one hour 2 hours later the setting temperature stops rising and indoor fan is fixed at low speed Anti cold wind function has the priority 3 4 8 3 Operation time in sleep mode is 7 hours After 7 hours the AC quits this mode and turns off 3 4 8 4 Timer setting is available 3 4 9 Auto Restart function The indoor unit is equipped with auto restart function w...

Страница 17: ...temperature will control the unit according to the room temperature detected from its own room temperature sensor and setting temperature Press the silence button on remote controller to initiate SILENCE function When the Silence function is activated the compressor running frequency will keep lower than F2 and the indoor unit will bring faint breeze which will reduce the noise to the lowest level...

Страница 18: ...serve 3 Reserve 4 Reserve 5 Reserve 6 Reserve L Reserve A Reserve U Reserve T When the AC enter into the information enquiry status it will display the code value in the next 25s the details are as follows 3 4 16 Point check function Press the LED DISPLAY or LED or MUTE button of the remote controller three times and then press the AIR DIRECTION or SWING button three times in ten seconds the buzze...

Страница 19: ...139 E0 E1 E9 140 141 149 F0 F1 F9 150 151 159 Indoor fan speed Outdoor fan speed 0 OFF 1 2 3 4 Low speed Medium speed High speed Turbo For some big capacity motors 14 FF Actual fan speed Display value turns to decimal value and then multiply 10 The unit is RPM For some small capacity motors display value is from 14 FF hexadecimal the corresponding fan speed range is from 200 2550RPM EXV opening an...

Страница 20: ...36341070 Fax 98 71 36341094 Tehran office No 19 koohe nour St Motahhari St TEHRAN IRAN Post code 15876 73111 Tel 98 21 89389 Fax 98 21 88541903 Ahwaz office No 309 Kaveh St AHWAZ IRAN Post code 61939 47911 Tel 98 61 32230647 8 Fax 98 61 32230647 E mail info trustacs com Web site http www trustacs com Air Conditioning Systems Cooling Heating ...

Отзывы: